TY - JOUR
T1 - Accuracy of LED and halogen radiometers using different light sources
AU - Roberts, Howard W.
AU - Vandewalle, Kraig S.
AU - Berzins, David W.
AU - Charlton, David G.
PY - 2006
Y1 - 2006
N2 - Purpose: To determine the accuracy of commercially available, handheld light-emitting diode (LED) and halogen-based radiometers using LED and quartz-tungsten-halogen (QTH) curing lights with light guides of various diameters. Methods: The irradiance of an LED curing light (L.E.Demetron I, SDS/Kerr, Orange, CA, USA) and a QTH curing light (Optilux 501, SDS/Kerr) were measured using multiple units of an LED (Demetron L.E.D. Radiometer, SDS/Kerr) and a halogen radiometer (Demetron 100, SDS/Kerr) and compared with each other and to a laboratory-grade power meter (control). Measurements were made using five light guides with distal light guide diameters of 4, 7, 8, 10, and 12.5 mm. For each light guide, five readings were made with each of three radiometers of each radiometer type. Data were analyzed with two-way analysis of variance/Tukey; α = 0.05. Results: In general, both handheld radiometer types exhibited significantly different irradiance readings compared with the control meter. Additionally, readings between radiometer types were found to differ slightly, but were correlated. In general, the LED radiometer provided slightly lower irradiance readings than the halogen radiometer, irrespective of light source. With both types of handheld radiometers, the use of the larger-diameter light guides tended to overestimate the irradiance values as seen in the control, while smaller-diameter light guides tended to underestimate.
AB - Purpose: To determine the accuracy of commercially available, handheld light-emitting diode (LED) and halogen-based radiometers using LED and quartz-tungsten-halogen (QTH) curing lights with light guides of various diameters. Methods: The irradiance of an LED curing light (L.E.Demetron I, SDS/Kerr, Orange, CA, USA) and a QTH curing light (Optilux 501, SDS/Kerr) were measured using multiple units of an LED (Demetron L.E.D. Radiometer, SDS/Kerr) and a halogen radiometer (Demetron 100, SDS/Kerr) and compared with each other and to a laboratory-grade power meter (control). Measurements were made using five light guides with distal light guide diameters of 4, 7, 8, 10, and 12.5 mm. For each light guide, five readings were made with each of three radiometers of each radiometer type. Data were analyzed with two-way analysis of variance/Tukey; α = 0.05. Results: In general, both handheld radiometer types exhibited significantly different irradiance readings compared with the control meter. Additionally, readings between radiometer types were found to differ slightly, but were correlated. In general, the LED radiometer provided slightly lower irradiance readings than the halogen radiometer, irrespective of light source. With both types of handheld radiometers, the use of the larger-diameter light guides tended to overestimate the irradiance values as seen in the control, while smaller-diameter light guides tended to underestimate.
UR - http://www.scopus.com/inward/record.url?scp=33748480675&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33748480675&partnerID=8YFLogxK
U2 - 10.1111/j.1708-8240.2006.00023.x
DO - 10.1111/j.1708-8240.2006.00023.x
M3 - Article
C2 - 16911424
AN - SCOPUS:33748480675
SN - 1496-4155
VL - 18
SP - 214
EP - 222
JO - Journal of Esthetic and Restorative Dentistry
JF - Journal of Esthetic and Restorative Dentistry
IS - 4
ER -