T1 - Cardiac resynchronization therapy and clinical outcomes in continuous flow left ventricular assist device recipients
AU - Gopinathannair, Rakesh
AU - Roukoz, Henri
AU - Bhan, Adarsh
AU - Ravichandran, Ashwin
AU - Ahmed, Mustafa M.
AU - Familtsev, Dmitry
AU - Bhat, Geetha
AU - Cowger, Jennifer
AU - Abdullah, Munazzah
AU - Sandesara, Chirag
AU - Dhawan, Rahul
AU - Birks, Emma J.
AU - Trivedi, Jaimin R.
AU - Slaughter, Mark S.
N1 - Publisher Copyright:
© 2018 The Authors.
PY - 2018/6/1
Y1 - 2018/6/1
N2 - Background--Many patients with heart failure continue cardiac resynchronization therapy (CRT) after continuous flow left ventricular assist device (CF-LVAD) implant. We report the first multicenter study to assess the impact of CRT on clinical outcomes in CF-LVAD patients. Methods and Results--Analysis was performed on 488 patients (58±13 years, 81% male) with an implantable cardioverter defibrillator (ICD) (n=223) or CRT-D (n=265) who underwent CF-LVAD implantation at 5 centers from 2007 to 2015. Effects of CRT on mortality, hospitalizations, and ventricular arrhythmia incidence were compared against CF-LVAD patients with an ICD alone. Baseline differences were noted between the 2 groups in age (60±12 versus 55±14, P < 0.001) and QRS duration (159±29 versus 126±34, P=0.001). Median biventricular pacing in the CRT group was 96%. During a median follow-up of 478 days, Kaplan-Meier analysis showed no difference in survival between groups (log rank P=0.28). Multivariate Cox regression demonstrated no survival benefit with type of device (ICD versus CRT-D; P=0.16), whereas use of amiodarone was associated with increased mortality (hazard ratio 1.77, 95% confidence interval 1.1-2.8, P=0.01). No differences were noted between CRT and ICD groups in all-cause (P=0.06) and heart failure (P=0.9) hospitalizations, ventricular arrhythmia incidence (43% versus 39%, P=0.3), or ICD shocks (35% versus 29%, P=0.2). During follow-up, 69 (26%) patients underwent pulse generator replacement in the CRT-D group compared with 36 (15.5%) in the ICD group (P=0.003). Conclusions--In this large, multicenter CF-LVAD cohort, continued CRT was not associated with improved survival, hospitalizations, incidence of ventricular arrhythmia and ICD therapies, and was related to a significantly higher number of pulse generator changes.
AB - Background--Many patients with heart failure continue cardiac resynchronization therapy (CRT) after continuous flow left ventricular assist device (CF-LVAD) implant. We report the first multicenter study to assess the impact of CRT on clinical outcomes in CF-LVAD patients. Methods and Results--Analysis was performed on 488 patients (58±13 years, 81% male) with an implantable cardioverter defibrillator (ICD) (n=223) or CRT-D (n=265) who underwent CF-LVAD implantation at 5 centers from 2007 to 2015. Effects of CRT on mortality, hospitalizations, and ventricular arrhythmia incidence were compared against CF-LVAD patients with an ICD alone. Baseline differences were noted between the 2 groups in age (60±12 versus 55±14, P < 0.001) and QRS duration (159±29 versus 126±34, P=0.001). Median biventricular pacing in the CRT group was 96%. During a median follow-up of 478 days, Kaplan-Meier analysis showed no difference in survival between groups (log rank P=0.28). Multivariate Cox regression demonstrated no survival benefit with type of device (ICD versus CRT-D; P=0.16), whereas use of amiodarone was associated with increased mortality (hazard ratio 1.77, 95% confidence interval 1.1-2.8, P=0.01). No differences were noted between CRT and ICD groups in all-cause (P=0.06) and heart failure (P=0.9) hospitalizations, ventricular arrhythmia incidence (43% versus 39%, P=0.3), or ICD shocks (35% versus 29%, P=0.2). During follow-up, 69 (26%) patients underwent pulse generator replacement in the CRT-D group compared with 36 (15.5%) in the ICD group (P=0.003). Conclusions--In this large, multicenter CF-LVAD cohort, continued CRT was not associated with improved survival, hospitalizations, incidence of ventricular arrhythmia and ICD therapies, and was related to a significantly higher number of pulse generator changes.
KW - Cardiac resynchronization therapy
KW - Heart failure
KW - Implanted cardioverter defibrillator
KW - Left ventricular assist device
KW - Ventricular arrhythmia
UR - http://www.scopus.com/inward/record.url?scp=85049129404&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85049129404&partnerID=8YFLogxK
U2 - 10.1161/JAHA.118.009091
DO - 10.1161/JAHA.118.009091
M3 - Article
C2 - 29907652
AN - SCOPUS:85049129404
SN - 2047-9980
VL - 7
JO - Journal of the American Heart Association
JF - Journal of the American Heart Association
IS - 12
M1 - e009091
ER -