TY - JOUR
T1 - Chronologic changes and correlates of loop diuretic dose in patients with left ventricular assist device
AU - Kido, Kazuhiko
AU - George, Bennet
AU - Charnigo, Richard J.
AU - Macaulay, Tracy E.
AU - Brouse, Sara D.
AU - Guglin, Maya
PY - 2017/3/20
Y1 - 2017/3/20
N2 - No study has systematically evaluated the prevalence and dosages of diuretic use for patients after left ventricular assist device (LVAD) implantation. The primary objective was to characterize chronologic change in prevalence and doses of loop diuretics after LVAD placement. The secondary objective was to identify correlates of actual doses of loop diuretics. We retrospectively reviewed medical records of adult patients with LVAD implantation at the University of Kentucky. Prevalence of diuretic use and furosemide equivalent dose were assessed before LVAD implantation and at seven time points thereafter: 1 week, 1 month, 3 months, 6 months, 1 year, 18 months, and 2 years. Correlation analyses and linear mixed modeling were used to identify correlates of diuretic dose before and after LVAD implantation. Eighty-two consecutive eligible patients were reviewed. The prevalence of loop diuretic use was 95% at baseline but significantly lower than that at all subsequent time points (p < 0.048 for all). Nevertheless, more than half of patients on whom we had such follow-up data were on loop diuretics 2 years after LVAD implantation. Average furosemide equivalent dose was significantly lower at every time point after implantation compared with baseline (p < 0.006 for all). Blood urine nitrogen (BUN) was the most robust predictor of dose after LVAD implant. The prevalence and average furosemide equivalent dose were significantly reduced after LVAD implantation, but the use of loop diuretic remained more than 50% for up to 2 years. Consistent association with BUN may indirectly indicate overuse of diuretics post-LVAD implant.
AB - No study has systematically evaluated the prevalence and dosages of diuretic use for patients after left ventricular assist device (LVAD) implantation. The primary objective was to characterize chronologic change in prevalence and doses of loop diuretics after LVAD placement. The secondary objective was to identify correlates of actual doses of loop diuretics. We retrospectively reviewed medical records of adult patients with LVAD implantation at the University of Kentucky. Prevalence of diuretic use and furosemide equivalent dose were assessed before LVAD implantation and at seven time points thereafter: 1 week, 1 month, 3 months, 6 months, 1 year, 18 months, and 2 years. Correlation analyses and linear mixed modeling were used to identify correlates of diuretic dose before and after LVAD implantation. Eighty-two consecutive eligible patients were reviewed. The prevalence of loop diuretic use was 95% at baseline but significantly lower than that at all subsequent time points (p < 0.048 for all). Nevertheless, more than half of patients on whom we had such follow-up data were on loop diuretics 2 years after LVAD implantation. Average furosemide equivalent dose was significantly lower at every time point after implantation compared with baseline (p < 0.006 for all). Blood urine nitrogen (BUN) was the most robust predictor of dose after LVAD implant. The prevalence and average furosemide equivalent dose were significantly reduced after LVAD implantation, but the use of loop diuretic remained more than 50% for up to 2 years. Consistent association with BUN may indirectly indicate overuse of diuretics post-LVAD implant.
KW - Furosemide
KW - Heart failure
KW - Left ventricular assist device
KW - Loop diuretic
UR - http://www.scopus.com/inward/record.url?scp=85015908710&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85015908710&partnerID=8YFLogxK
U2 - 10.1097/MAT.0000000000000565
DO - 10.1097/MAT.0000000000000565
M3 - Article
C2 - 28328556
AN - SCOPUS:85015908710
SN - 1058-2916
VL - 63
SP - 774
EP - 780
JO - ASAIO Journal
JF - ASAIO Journal
IS - 6
ER -