T1 - Correlation of bone tunnel diameter with quadrupled hamstring graft fixation strength using a biodegradable interference screw
AU - Steenlage, Eric
AU - Brand, Jeff C.
AU - Johnson, Darren L.
AU - Caborn, David N.M.
PY - 2002/10
Y1 - 2002/10
N2 - Purpose: The purpose of this study was to determine whether the ultimate load at failure of a quadrupled hamstring tendon graft (QHT) fixed with a biodegradable interference screw is improved with a more precise match of the bone tunnel diameter to the diameter of the QHT. Type of Study: Biomechanical testing. Methods: In group A, 8 cadaver knees with a mean age of 69.4 years (range, 60 to 76) were used. QHT graft diameters were measured using sleeves in standard 1.0-mm increments, with matching bone tunnels drilled in 1.0-mm increments. In group B, 9 cadaver knees, with a mean age of 66.5 (53 to 81) were used. Grafts were measured using sleeves in 0.5-mm increments and matching bone tunnels in 0.5-mm increments were drilled. In both groups, the QHT grafts were fixed with a biodegradable interference screw (BioScrew, Linvatec, Largo, FL) in both the tibia and the femur. Tendon interference fixation was tested to failure using a material testing device that tensioned the grafts directly in line with the bone tunnels. Bone mineral density was measured using dual photon absorptimetry for the metaphyseal area of the tibias and femora in the area of interference screw fixation. Results: Femoral maximum load at failure significantly improved from 341 N in the 1.0-mm group to 530 N (P < .05) in the 0.5-mm group; the tibial maximum load at failure improved from 221 N to 308 N (P = .35). Conclusions: Fixation strength results of this study suggest that commercially available instrumentation could be improved with sleeves and reamers available in 0.5-mm increments.
AB - Purpose: The purpose of this study was to determine whether the ultimate load at failure of a quadrupled hamstring tendon graft (QHT) fixed with a biodegradable interference screw is improved with a more precise match of the bone tunnel diameter to the diameter of the QHT. Type of Study: Biomechanical testing. Methods: In group A, 8 cadaver knees with a mean age of 69.4 years (range, 60 to 76) were used. QHT graft diameters were measured using sleeves in standard 1.0-mm increments, with matching bone tunnels drilled in 1.0-mm increments. In group B, 9 cadaver knees, with a mean age of 66.5 (53 to 81) were used. Grafts were measured using sleeves in 0.5-mm increments and matching bone tunnels in 0.5-mm increments were drilled. In both groups, the QHT grafts were fixed with a biodegradable interference screw (BioScrew, Linvatec, Largo, FL) in both the tibia and the femur. Tendon interference fixation was tested to failure using a material testing device that tensioned the grafts directly in line with the bone tunnels. Bone mineral density was measured using dual photon absorptimetry for the metaphyseal area of the tibias and femora in the area of interference screw fixation. Results: Femoral maximum load at failure significantly improved from 341 N in the 1.0-mm group to 530 N (P < .05) in the 0.5-mm group; the tibial maximum load at failure improved from 221 N to 308 N (P = .35). Conclusions: Fixation strength results of this study suggest that commercially available instrumentation could be improved with sleeves and reamers available in 0.5-mm increments.
KW - Graft fixation
KW - Hamstring tendons
KW - Ligament reconstruction
UR - http://www.scopus.com/inward/record.url?scp=0036821542&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036821542&partnerID=8YFLogxK
U2 - 10.1053/jars.2002.36138
DO - 10.1053/jars.2002.36138
M3 - Article
C2 - 12368789
AN - SCOPUS:0036821542
SN - 0749-8063
VL - 18
SP - 901
EP - 907
JO - Arthroscopy
JF - Arthroscopy
IS - 8
ER -