TY - GEN
T1 - Creep evaluation of (orthotic) cast materials during simulated clubfoot correction
AU - Cohen, Tamara L.
AU - Altiok, Haluk
AU - Tarima, Sergey
AU - Smith, Peter A.
AU - Harris, Gerald F.
PY - 2012
Y1 - 2012
N2 - The Ponseti method is a widely accepted and highly successful conservative treatment of pediatric clubfoot that relies on weekly manipulations and cast applications. However, the material behavior of the cast in the Ponseti technique has not been investigated. The current study sought to characterize the ability of two standard casting materials to maintain the Ponseti corrected foot position by evaluating creep response. A dynamic cast testing device (DCTD) was built to simulate a typical pediatric clubfoot. Semi-rigid fiberglass and rigid fiberglass casting materials were applied to the device, and the rotational creep was measured at various constant torques. The movement was measured using a 3D motion capture system. A 2-way ANOVA was performed on the creep displacement data at a significance level of 0.05. Among cast materials, the rotational creep displacement was found to be significantly different (p-values 0.001). The most creep displacement occurs in the semi-rigid fiberglass (approximately 1.0 degrees), then the rigid fiberglass (approximately 0.4 degrees). There was no effect of torque magnitude on the creep displacement. All materials maintained the corrected position with minimal change in position over time.
AB - The Ponseti method is a widely accepted and highly successful conservative treatment of pediatric clubfoot that relies on weekly manipulations and cast applications. However, the material behavior of the cast in the Ponseti technique has not been investigated. The current study sought to characterize the ability of two standard casting materials to maintain the Ponseti corrected foot position by evaluating creep response. A dynamic cast testing device (DCTD) was built to simulate a typical pediatric clubfoot. Semi-rigid fiberglass and rigid fiberglass casting materials were applied to the device, and the rotational creep was measured at various constant torques. The movement was measured using a 3D motion capture system. A 2-way ANOVA was performed on the creep displacement data at a significance level of 0.05. Among cast materials, the rotational creep displacement was found to be significantly different (p-values 0.001). The most creep displacement occurs in the semi-rigid fiberglass (approximately 1.0 degrees), then the rigid fiberglass (approximately 0.4 degrees). There was no effect of torque magnitude on the creep displacement. All materials maintained the corrected position with minimal change in position over time.
UR - https://www.scopus.com/pages/publications/84870849012
UR - https://www.scopus.com/pages/publications/84870849012#tab=citedBy
U2 - 10.1109/EMBC.2012.6346683
DO - 10.1109/EMBC.2012.6346683
M3 - Conference contribution
C2 - 23366644
AN - SCOPUS:84870849012
SN - 9781424441198
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 3352
EP - 3355
BT - 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012
T2 - 34th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2012
Y2 - 28 August 2012 through 1 September 2012
ER -