TY - JOUR
T1 - Data on spectrum-based fluorescence resonance energy transfer measurement of E. coli multidrug transporter AcrB
AU - Cai, Yuguang
AU - Wilkop, Thomas
AU - Wei, Yinan
N1 - Publisher Copyright:
© 2018 The Authors
PY - 2018/12
Y1 - 2018/12
N2 - This paper presented the dataset of correction parameters used in the determination of the energy transfer efficiencies from the spectrum-based fluorescence resonance energy transfer (FRET) measurement in a trimeric membrane protein AcrB. The cyan fluorescent protein (CFP) and yellow fluorescent protein (YPet) were used as the donor and acceptor, respectively. Two AcrB fusion proteins were constructed, AcrB-CFP and AcrB-YPet. The proteins were co-expressed in Escherichia coli cells, and energy transfer efficiency were determined in live cells. To obtain reliable energy transfer data, a complete set of correction parameters need to be first determined to accommodate for factors such as background fluorescence and spectra overlap. This paper described the methodology and determination of the correction factors, which are useful data and reference points for researchers working on fluorescence measurement of membrane protein complexes in live bacteria cells. Further interpretation and discussion of these data can be found in “Comparison of in vitro and in vivo oligomeric states of a wild type and mutant trimeric inner membrane multidrug transporter” (Wang et al., in press).
AB - This paper presented the dataset of correction parameters used in the determination of the energy transfer efficiencies from the spectrum-based fluorescence resonance energy transfer (FRET) measurement in a trimeric membrane protein AcrB. The cyan fluorescent protein (CFP) and yellow fluorescent protein (YPet) were used as the donor and acceptor, respectively. Two AcrB fusion proteins were constructed, AcrB-CFP and AcrB-YPet. The proteins were co-expressed in Escherichia coli cells, and energy transfer efficiency were determined in live cells. To obtain reliable energy transfer data, a complete set of correction parameters need to be first determined to accommodate for factors such as background fluorescence and spectra overlap. This paper described the methodology and determination of the correction factors, which are useful data and reference points for researchers working on fluorescence measurement of membrane protein complexes in live bacteria cells. Further interpretation and discussion of these data can be found in “Comparison of in vitro and in vivo oligomeric states of a wild type and mutant trimeric inner membrane multidrug transporter” (Wang et al., in press).
UR - http://www.scopus.com/inward/record.url?scp=85055686924&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85055686924&partnerID=8YFLogxK
U2 - 10.1016/j.dib.2018.10.155
DO - 10.1016/j.dib.2018.10.155
M3 - Article
AN - SCOPUS:85055686924
SN - 2352-3409
VL - 21
SP - 1649
EP - 1653
JO - Data in Brief
JF - Data in Brief
ER -