TY - JOUR
T1 - Dose buildup for obliquely incident photon beams
AU - Gerbi, Bruce J.
AU - Meigooni, Ali S.
AU - Khan, Faiz M.
PY - 1987/5
Y1 - 1987/5
N2 - For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane parallel ionization chamber in a polystyrene phantom with obliquely incident 6, 10, 18, and 24 MV x ray beams angled 0° to 84°. Buildup curves at these angles were plotted and from these an obliquity factor, defined as the ratio of ionization charge collected at a point for a particular angle of incidence to that collected at the same point at normal incidence, was determined. For each energy, the obliquity factor as a function of depth, field size, and source–chamber distance was studied. Results indicate that the obliquity factor is highly dependent on the beam energy, angle of incidence, the collimator opening, and the source–skin distance. A mathematical expression has been developed to predict the dose in the buildup region of high energy photon beams for various angles of beam incidence, field size, and chamber distance.
AB - For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane parallel ionization chamber in a polystyrene phantom with obliquely incident 6, 10, 18, and 24 MV x ray beams angled 0° to 84°. Buildup curves at these angles were plotted and from these an obliquity factor, defined as the ratio of ionization charge collected at a point for a particular angle of incidence to that collected at the same point at normal incidence, was determined. For each energy, the obliquity factor as a function of depth, field size, and source–chamber distance was studied. Results indicate that the obliquity factor is highly dependent on the beam energy, angle of incidence, the collimator opening, and the source–skin distance. A mathematical expression has been developed to predict the dose in the buildup region of high energy photon beams for various angles of beam incidence, field size, and chamber distance.
KW - BUILDUP
KW - DEPTH DOSE DISTRIBUTIONS
KW - PHANTOMS
KW - PHOTON BEAMS
KW - POLYSTYRENE
KW - RADIOTHERAPY
KW - X-RAY DOSIMETRY
UR - https://www.scopus.com/pages/publications/0023196050
UR - https://www.scopus.com/pages/publications/0023196050#tab=citedBy
U2 - 10.1118/1.596055
DO - 10.1118/1.596055
M3 - Letter
C2 - 3600530
AN - SCOPUS:0023196050
SN - 0094-2405
VL - 14
SP - 393
EP - 399
JO - Medical Physics
JF - Medical Physics
IS - 3
ER -