Dose reduction while preserving diagnostic quality in head CT: Advancing the application of iterative reconstruction using a live animal model

F. D. Raslau, E. J. Escott, J. Smiley, C. Adams, D. Feigal, H. Ganesh, C. Wang, J. Zhang

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

BACKGROUND AND PURPOSE: Iterative reconstruction has promise in lowering the radiation dose without compromising image quality, but its full potential has not yet been realized. While phantom studies cannot fully approximate the subjective effects on image quality, live animal models afford this assessment. We characterize dose reduction in head CT by applying advanced modeled iterative reconstruction (ADMIRE) in a live ovine model while evaluating preservation of gray-white matter detectability and image texture compared with filtered back-projection. MATERIALS AND METHODS: A live sheep was scanned on a Force CT scanner (Siemens) at 12 dose levels (82-982 effective mAs). Images were reconstructed with filtered back-projection and ADMIRE (strengths, 1-5). A total of 72 combinations (12 doses × 6 reconstructions) were evaluated qualitatively for resemblance to the reference image (highest dose with filtered back-projection) using 2 metrics: detectability of gray-white matter differentiation and noise-versus-smoothness in image texture. Quantitative analysis for noise, SNR, and contrast-to-noise was also performed across all dose-strength combinations. RESULTS: Both qualitative and quantitative results confirm that gray-white matter differentiation suffers at a lower dose but recovers when complemented by higher iterative reconstruction strength, and image texture acquires excessive smoothness with a higher iterative reconstruction strength but recovers when complemented by dose reduction. Image quality equivalent to the reference image is achieved by a 58% dose reduction with ADMIRE-5. CONCLUSIONS: An approximately 60% dose reduction may be possible while preserving diagnostic quality with the appropriate dose-strength combination. This in vivo study can serve as a useful guide for translating the full implementation of iterative reconstruction in clinical practice.

Original languageEnglish
Pages (from-to)1864-1870
Number of pages7
JournalAmerican Journal of Neuroradiology
Volume40
Issue number11
DOIs
StatePublished - 2019

Bibliographical note

Publisher Copyright:
© 2019 American Society of Neuroradiology. All rights reserved.

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Clinical Neurology

Fingerprint

Dive into the research topics of 'Dose reduction while preserving diagnostic quality in head CT: Advancing the application of iterative reconstruction using a live animal model'. Together they form a unique fingerprint.

Cite this