Effect of cornea preservation time on success of descemet stripping automated endothelial keratoplasty a randomized clinical trial

Research output: Contribution to journalArticlepeer-review

50 Scopus citations

Abstract

IMPORTANCE Demonstrating that success of Descemet stripping automated endothelial keratoplasty is similar across donor cornea preservation times (PTs) could increase the donor pool. OBJECTIVE To determine whether the 3-year rate of graft success using corneal donor tissue preserved 8 to 14 days is noninferior to that of donor tissue preserved 7 days or less. DESIGN, SETTING, AND PARTICIPANTS A multicenter, double-masked, randomized noninferiority clinical trial was conducted from April 16, 2012, to June 5, 2017, at 40 clinical sites (70 surgeons) in the United States, with donor corneas provided by 23 US eye banks. A total of 1090 individuals (1330 study eyes) underwent Descemet stripping automated endothelial keratoplasty (1255 eyes [94.4%] for Fuchs endothelial corneal dystrophy). INTERVENTIONS Descemet stripping automated endothelial keratoplasty with random assignment of a donor cornea with a PT of 7 days or less (0-7d PT) or 8 to 14 days (8-14d PT). MAIN OUTCOMES AND MEASURES Graft success at 3 years. RESULTS Of the 1090 participants (1330 study eyes; 60.2%women and 39.8%men; median age at enrollment, 70 years [range, 42-90 years]), the 3-year cumulative probability of graft success was 95.3%(95%CI, 93.6%-96.9%) in the 0-7d PT group and 92.1%(95%CI, 89.9%-94.2%) in the 8-14d PT group (difference, 3.2%). The upper limit of the 1-sided 95%CI on the difference was 5.4%, exceeding the prespecified noninferiority limit of 4%. The difference was mostly owing to more primary donor failures in the 8-14d PT group, with the conditional probability of failure after the first month being 2.4%in the 0-7d PT group and 3.1% in the 8-14d PT group. In preplanned secondary analyses, longer PT was associated with a lower rate of graft success (unadjusted hazard ratio for graft failure per additional day of PT, 1.10; 95%CI, 1.03-1.18; P = .008 [PT analyzed as days]), with success rates of 96.5%(95%CI, 92.3%-98.4%) for PT of 4 days or less, 94.9%(95%CI, 92.5%-96.6%) for PT of 5 to 7 days, 93.8% (95%CI, 91.0%-95.8%) for PT of 8 to 11 days, and 89.3%(95%CI, 84.4%-92.7%) for PT of 12 to 14 days (P = .01 [PT analyzed as categorical variable]). CONCLUSIONS AND RELEVANCE The 3-year success rate in eyes undergoing Descemet stripping automated endothelial keratoplasty was high irrespective of PT. However, the study was unable to conclude that the success rate with donor corneas preserved 8 to 14 days was similar to that of corneas preserved 7 days or less with respect to the prespecified noninferiority limit. Although longer PT was associated with a lower success rate, the difference in rates was small when PT was less than 12 days.

Original languageEnglish
Pages (from-to)1401-1409
Number of pages9
JournalJAMA Ophthalmology
Volume135
Issue number12
DOIs
StatePublished - Dec 1 2017

Bibliographical note

Publisher Copyright:
© 2017 American Medical Association. All rights reserved.

Funding

Funding/Support: The study was supported by cooperative agreements EY20797 and EY20798 with the National Eye Institute, National Institutes of Health, Department of Health and Human Services.

FundersFunder number
National Institutes of Health (NIH)
U.S. Department of Health and Human Services
National Eye Institute (NEI)

    ASJC Scopus subject areas

    • Ophthalmology

    Fingerprint

    Dive into the research topics of 'Effect of cornea preservation time on success of descemet stripping automated endothelial keratoplasty a randomized clinical trial'. Together they form a unique fingerprint.

    Cite this