T1 - Effects of an Intervention to Increase Bed Alarm Use to Prevent Falls in Hospitalized Patients
T2 - A Cluster Randomized Trial
AU - Shorr, Ronald I.
AU - Michelle Chandler, A.
AU - Mion, Lorraine C.
AU - Waters, Teresa M.
AU - Liu, Minzhao
AU - Daniels, Michael J.
AU - Kessler, Lori A.
AU - Miller, Stephen T.
PY - 2012/11/20
Y1 - 2012/11/20
N2 - Background: Bed alarm systems intended to prevent hospital falls have not been formally evaluated. Objective: To investigate whether an intervention aimed at increasing bed alarm use decreases hospital falls and related events. Design: Pair-matched, cluster randomized trial over 18 months. Nursing units were allocated by computer-generated randomization on the basis of baseline fall rates. Patients and outcome assessors were blinded to unit assignment; outcome assessors may have become unblinded. (ClinicalTrials.gov registration number: NCT00183053) Setting: 16 nursing units in an urban community hospital. Patients: 27 672 inpatients in general medical, surgical, and specialty units. Intervention: Education, training, and technical support to promote use of a standard bed alarm system (intervention units); bed alarms available but not formally promoted or supported (control units). Measurements: Pre-post difference in change in falls per 1000 patient-days (primary end point); number of patients who fell, fall-related injuries, and number of patients restrained (secondary end points). Results: Prevalence of alarm use was 64.41 days per 1000 patientdays on intervention units and 1.79 days per 1000 patient-days on control units (P = 0.004). There was no difference in change in fall rates per 1000 patient-days (risk ratio, 1.09 [95% CI, 0.85 to 1.53]; difference, 0.41 [CI, -1.05 to 2.47], which corresponds to a greater difference in falls in control vs. intervention units) or in the number of patients who fell, injurious fall rates, or the number of patients physically restrained on intervention units compared with control units. Limitation: The study was conducted at a single site and was slightly underpowered compared with the initial design. Conclusion: An intervention designed to increase bed alarm use in an urban hospital increased alarm use but had no statistically or clinically significant effect on fall-related events or physical restraint use. Primary Funding Source: National Institute on Aging.
AB - Background: Bed alarm systems intended to prevent hospital falls have not been formally evaluated. Objective: To investigate whether an intervention aimed at increasing bed alarm use decreases hospital falls and related events. Design: Pair-matched, cluster randomized trial over 18 months. Nursing units were allocated by computer-generated randomization on the basis of baseline fall rates. Patients and outcome assessors were blinded to unit assignment; outcome assessors may have become unblinded. (ClinicalTrials.gov registration number: NCT00183053) Setting: 16 nursing units in an urban community hospital. Patients: 27 672 inpatients in general medical, surgical, and specialty units. Intervention: Education, training, and technical support to promote use of a standard bed alarm system (intervention units); bed alarms available but not formally promoted or supported (control units). Measurements: Pre-post difference in change in falls per 1000 patient-days (primary end point); number of patients who fell, fall-related injuries, and number of patients restrained (secondary end points). Results: Prevalence of alarm use was 64.41 days per 1000 patientdays on intervention units and 1.79 days per 1000 patient-days on control units (P = 0.004). There was no difference in change in fall rates per 1000 patient-days (risk ratio, 1.09 [95% CI, 0.85 to 1.53]; difference, 0.41 [CI, -1.05 to 2.47], which corresponds to a greater difference in falls in control vs. intervention units) or in the number of patients who fell, injurious fall rates, or the number of patients physically restrained on intervention units compared with control units. Limitation: The study was conducted at a single site and was slightly underpowered compared with the initial design. Conclusion: An intervention designed to increase bed alarm use in an urban hospital increased alarm use but had no statistically or clinically significant effect on fall-related events or physical restraint use. Primary Funding Source: National Institute on Aging.
UR - http://www.scopus.com/inward/record.url?scp=84872853387&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84872853387&partnerID=8YFLogxK
U2 - 10.7326/0003-4819-157-10-201211200-00005
DO - 10.7326/0003-4819-157-10-201211200-00005
M3 - Article
C2 - 23165660
AN - SCOPUS:84872853387
VL - 157
SP - 692
EP - 699
IS - 10
ER -