T1 - Hematologic markers better predict left ventricular assist device thrombosis than echocardiographic or pump parameters
AU - Bartoli, Carlo R.
AU - Ghotra, Amaninderapal S.
AU - Pachika, Ajay R.
AU - Birks, Emma J.
AU - McCants, Kelly C.
PY - 2014/8
Y1 - 2014/8
N2 - Background Left ventricular assist device (LVAD) thrombosis is a life-threatening complication that remains a major clinical problem. Consensus diagnostic criteria do not exist. We investigated whether hematologic, echocardiographic, or pump parameters reliably change during LVAD thrombosis. Methods A retrospective analysis of 20 consecutive cases of continuous-flow LVAD thrombosis (Thoratec HeartMate II n = 16, HeartWare HVAD n = 4) was performed. Hematologic markers (lactate dehydrogenase, plasma-free hemoglobin, hemoglobin, creatinine), echocardiographic parameters (left ventricular end-systolic and end-diastolic diameter, mitral regurgitation, aortic insufficiency, inflow-cannula velocity), and pump characteristics (speed, power, estimated flow, pulsatility index) were analyzed with one-way repeated measures ANOVA with Tukey post-test or paired Student t-tests. Results Lactate dehydrogenase and plasma-free hemoglobin were significantly (p < 0.05) elevated at admission for LVAD thrombosis. Hemoglobin and creatinine were not significantly different at admission but changed significantly after admission. Left ventricular end-systolic and end-diastolic diameter, mitral regurgitation, aortic insufficiency, inflow-cannula velocity, LVAD speed, power consumption, estimated flow, and pulsatility index were not significantly different at admission for LVAD thrombosis. Conclusion Hematological markers of hemolysis, but not echocardiographic or pump parameters, reliably changed during LVAD thrombosis. Markers of hemolysis are the best early predictors of LVAD thrombosis.
AB - Background Left ventricular assist device (LVAD) thrombosis is a life-threatening complication that remains a major clinical problem. Consensus diagnostic criteria do not exist. We investigated whether hematologic, echocardiographic, or pump parameters reliably change during LVAD thrombosis. Methods A retrospective analysis of 20 consecutive cases of continuous-flow LVAD thrombosis (Thoratec HeartMate II n = 16, HeartWare HVAD n = 4) was performed. Hematologic markers (lactate dehydrogenase, plasma-free hemoglobin, hemoglobin, creatinine), echocardiographic parameters (left ventricular end-systolic and end-diastolic diameter, mitral regurgitation, aortic insufficiency, inflow-cannula velocity), and pump characteristics (speed, power, estimated flow, pulsatility index) were analyzed with one-way repeated measures ANOVA with Tukey post-test or paired Student t-tests. Results Lactate dehydrogenase and plasma-free hemoglobin were significantly (p < 0.05) elevated at admission for LVAD thrombosis. Hemoglobin and creatinine were not significantly different at admission but changed significantly after admission. Left ventricular end-systolic and end-diastolic diameter, mitral regurgitation, aortic insufficiency, inflow-cannula velocity, LVAD speed, power consumption, estimated flow, and pulsatility index were not significantly different at admission for LVAD thrombosis. Conclusion Hematological markers of hemolysis, but not echocardiographic or pump parameters, reliably changed during LVAD thrombosis. Markers of hemolysis are the best early predictors of LVAD thrombosis.
KW - heart failure
KW - left ventricular assist device
KW - mechanical circulatory support
KW - thrombosis
UR - http://www.scopus.com/inward/record.url?scp=84906326682&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84906326682&partnerID=8YFLogxK
U2 - 10.1055/s-0034-1376891
DO - 10.1055/s-0034-1376891
M3 - Article
C2 - 24995532
AN - SCOPUS:84906326682
SN - 0171-6425
VL - 62
SP - 414
EP - 418
JO - Thoracic and Cardiovascular Surgeon
JF - Thoracic and Cardiovascular Surgeon
IS - 5
ER -