High performance infiltrant-free cryogenic machining of 82% density porous tungsten under computer numerical control

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

3 Scopus citations

Abstract

Cryogenic machining was used as a means to eliminate the conventional methyl-methacrylate infiltration process used in the manufacture of dispenser cathode matrices. The resulting surfaces were analyzed before and after impregnation to determine their suitability for dispenser cathodes.

Original languageEnglish
Title of host publicationIEEE International Vacuum Electronics Conference, IVEC 2014
Pages167-168
Number of pages2
DOIs
StatePublished - 2014
Event15th IEEE International Vacuum Electronics Conference, IVEC 2014 - Monterey, CA, United States
Duration: Apr 22 2014Apr 24 2014

Publication series

NameIEEE International Vacuum Electronics Conference, IVEC 2014

Conference

Conference15th IEEE International Vacuum Electronics Conference, IVEC 2014
Country/TerritoryUnited States
CityMonterey, CA
Period4/22/144/24/14

Keywords

  • cryogenic machining
  • dispenser cathode
  • porous tungsten
  • surface integrity

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'High performance infiltrant-free cryogenic machining of 82% density porous tungsten under computer numerical control'. Together they form a unique fingerprint.

Cite this