Skip to main navigation Skip to search Skip to main content

Inconsistent CT NSCLC radiomics associated with feature selection methods, predictive models and related factors

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Objective. To investigate potential uncertainties in CT-based non-small cell lung cancer (NSCLC) radiomics associated with feature selection methods, predictive models, and their related factors. Approach. CT images from 496 pre-Treatment NSCLC patients were retrospectively retrieved from a GE CT scanner. The original patient cohort (100%) was sampled to generate 25%, 50%, and 75% sub-cohorts to investigate potential impact of cohort size. Radiomic features were extracted from the lung nodule using IBEX. Five feature selection methods (analysis of variance, least absolute shrinkage and selection operator, mutual information, minimum redundancy-maximum relevance, Relief) and seven predictive models (DT-decision tree, RF-random forest, LR-logistic regression, SVC-support vector classifier, KNN-k-nearest neighbor, GB-gradient boost, NB-Naïve-Bayesian) were included for the analysis. Cohort size and cohort composition (i.e. same sized cohorts with partially different patients) were investigated as factors related to feature selection methods. The number of input features and model validation methods (2-, 5-, and 10-fold cross-validation) were investigated for predictive models. Using a two-year survival endpoint, AUC values were calculated for the various combinations. Main results. Features ranked by different feature selection methods are not consistent and dependent on cohort size, even for the same methods. Two methods, Relief and LASSO, select 17 and 14 features from 25 common features to all cohort sizes, respectively, while other 3 feature selection methods have <10 features common to all cohort sizes. Feature rankings also highly depend on minor differences in cohort composition. AUCs for the 2100 tested combinations vary from 0.427 to 0.973. Among them, only 16 combinations achieve an AUC > 0.65. There is no clear path to reliable CT NSCLC radiomics. Significance. The use of different feature selection methods and predictive models can generate inconsistent results. This should be further investigated to improve the reliability of radiomic studies.

Original languageEnglish
Article number125004
JournalPhysics in Medicine and Biology
Volume68
Issue number12
DOIs
StatePublished - Jun 21 2023

Bibliographical note

Publisher Copyright:
© 2023 Institute of Physics and Engineering in Medicine.

Funding

This study is not supported by any research grant.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • NSCLC
  • feature selection method
  • lung cancer
  • predictive model
  • radiomics

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Inconsistent CT NSCLC radiomics associated with feature selection methods, predictive models and related factors'. Together they form a unique fingerprint.

Cite this