TY - JOUR
T1 - Increased integrity of free circulating DNA in sera of patients with colorectal or periampullary cancer
T2 - Direct quantitative PCR for ALU repeats
AU - Umetani, Naoyuki
AU - Kim, Joseph
AU - Hiramatsu, Suzanne
AU - Reber, Howard A.
AU - Hines, Oscar J.
AU - Bilchik, Anton J.
AU - Hoon, Dave S.B.
PY - 2006/6
Y1 - 2006/6
N2 - Background: Cell-free DNA circulating in blood is a candidate biomarker for malignant tumors. Unlike uniformly truncated DNA released from apoptotic nondiseased cells, DNA released from dead cancer cells varies in size. We developed a novel method to measure the ratio of longer to shorter DNA fragments (DNA integrity) in serum as a potential biomarker for patients with colorectal cancer (CRC) or periampullary cancers (PACs). Methods: Sera from 32 patients with CRC (3 stage I, 14 stage II, 6 stage III, and 9 stage IV patients), 19 patients with PACs (2 stage I, 9 stage II, 1 stage III, and 7 stage IV patients), and 51 healthy volunteers were assessed by quantitative real-time PCR of ALU repeats (ALU-qPCR) with 2 sets of primers (115 and 247 bp) amplifying different lengths of DNA. We used serum directly as a template for ALU-qPCR without DNA purification. DNA integrity was determined as ratio of qPCR results of 247-bp ALU over 115-bp ALU. Results: ALU-qPCR had a detection limit of 0.01 pg of DNA. Eliminating DNA purification reduced technical artifacts and reagent/labor costs. Serum DNA integrity was significantly increased for stage I/II and III/IV CRC and stage I/II and III/IV PACs (P = 0.002, P = 0.006, P = 0.022, and P < 0.0001, respectively). ROC curves for detecting CRC and PACs had areas under the curves of 0.78 and 0.80, respectively. Conclusions: Direct ALU-qPCR is a robust, highly sensitive, and high-throughput method to measure serum DNA integrity. DNA integrity is a potential serum biomarker for detection and evaluation of CRC and PACs.
AB - Background: Cell-free DNA circulating in blood is a candidate biomarker for malignant tumors. Unlike uniformly truncated DNA released from apoptotic nondiseased cells, DNA released from dead cancer cells varies in size. We developed a novel method to measure the ratio of longer to shorter DNA fragments (DNA integrity) in serum as a potential biomarker for patients with colorectal cancer (CRC) or periampullary cancers (PACs). Methods: Sera from 32 patients with CRC (3 stage I, 14 stage II, 6 stage III, and 9 stage IV patients), 19 patients with PACs (2 stage I, 9 stage II, 1 stage III, and 7 stage IV patients), and 51 healthy volunteers were assessed by quantitative real-time PCR of ALU repeats (ALU-qPCR) with 2 sets of primers (115 and 247 bp) amplifying different lengths of DNA. We used serum directly as a template for ALU-qPCR without DNA purification. DNA integrity was determined as ratio of qPCR results of 247-bp ALU over 115-bp ALU. Results: ALU-qPCR had a detection limit of 0.01 pg of DNA. Eliminating DNA purification reduced technical artifacts and reagent/labor costs. Serum DNA integrity was significantly increased for stage I/II and III/IV CRC and stage I/II and III/IV PACs (P = 0.002, P = 0.006, P = 0.022, and P < 0.0001, respectively). ROC curves for detecting CRC and PACs had areas under the curves of 0.78 and 0.80, respectively. Conclusions: Direct ALU-qPCR is a robust, highly sensitive, and high-throughput method to measure serum DNA integrity. DNA integrity is a potential serum biomarker for detection and evaluation of CRC and PACs.
UR - http://www.scopus.com/inward/record.url?scp=33646935703&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33646935703&partnerID=8YFLogxK
U2 - 10.1373/clinchem.2006.068577
DO - 10.1373/clinchem.2006.068577
M3 - Article
C2 - 16723681
AN - SCOPUS:33646935703
SN - 0009-9147
VL - 52
SP - 1062
EP - 1069
JO - Clinical Chemistry
JF - Clinical Chemistry
IS - 6
ER -