TY - JOUR
T1 - Joint Report of the Second International Workshop on Lymphocyte Alloantigens of the Horse, held 3–8 October 1982
AU - Bailey, E.
AU - Antczak, D. F.
AU - Bernoco, D.
AU - Bull, R. W.
AU - Fister, R.
AU - Guerin, G.
AU - Lázary, S.
AU - Matthews, S.
AU - McClure, J.
AU - Meyer, J.
AU - Mottironi, V. D.
AU - Templeton, J.
PY - 1984/4
Y1 - 1984/4
N2 - The Second International Workshop on Lymphocyte Alloantigens of the Horse was held 3–8 October 1982. At this workshop, the 6 specificities identified at the first workshop were confirmed and an additional 5 new specificities were identified and given workshop nomenclature. Four of the new specificities, products of the ELA locus, were named ELA‐W7, W8, W9, and W10. An additional specificity, designated ELY‐2.1, is the product of a locus independent of the ELA locus. Cell isolation methods were compared at this workshop, Technical variation in methods clearly affected reactivity of many reagents. However, when highly selected reagents were used, antigen assignment did not differ regardless of the cell isolation method. Based on the comparison of methods, isolation procedures in which thrombin was used were more effective than those relying on carbonyl iron or slow centrifugation.
AB - The Second International Workshop on Lymphocyte Alloantigens of the Horse was held 3–8 October 1982. At this workshop, the 6 specificities identified at the first workshop were confirmed and an additional 5 new specificities were identified and given workshop nomenclature. Four of the new specificities, products of the ELA locus, were named ELA‐W7, W8, W9, and W10. An additional specificity, designated ELY‐2.1, is the product of a locus independent of the ELA locus. Cell isolation methods were compared at this workshop, Technical variation in methods clearly affected reactivity of many reagents. However, when highly selected reagents were used, antigen assignment did not differ regardless of the cell isolation method. Based on the comparison of methods, isolation procedures in which thrombin was used were more effective than those relying on carbonyl iron or slow centrifugation.
KW - MHC
KW - cellular antigens
KW - histocompatibility
KW - horse
KW - lymphocyte
UR - http://www.scopus.com/inward/record.url?scp=0021156924&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0021156924&partnerID=8YFLogxK
U2 - 10.1111/j.1365-2052.1984.tb01107.x
DO - 10.1111/j.1365-2052.1984.tb01107.x
M3 - Article
C2 - 6497059
AN - SCOPUS:0021156924
SN - 0003-3480
VL - 15
SP - 123
EP - 132
JO - Animal Blood Groups and Biochemical Genetics
JF - Animal Blood Groups and Biochemical Genetics
IS - 2
ER -