TY - JOUR
T1 - Mixed venous oxygen saturation during cardiopulmonary bypass poorly predicts regional venous saturation
AU - McDaniel, L. B.
AU - Zwischenberger, J. B.
AU - Vertrees, R. A.
AU - Nutt, L.
AU - Uchida, T.
AU - Nguyen, T.
AU - Kramer, G. C.
AU - McLellan, F.
PY - 1995
Y1 - 1995
N2 - Mixed venous oxygen saturation is generally accepted as an indicator of adequacy of systemic oxygen delivery; however, cardiopulmonary bypass (CPB) may alter this relationship. Major postoperative complications potentially secondary to inadequate oxygen delivery during CPB indicate that mixed venous oxygen saturation may not detect regional venous desaturation during CPB. We therefore tested the hypothesis that mixed venous oxygen saturation and pH did not predict regional venous oxygen saturations and pH during 2 h of bypass in a swine model. Six immature swine (27-34 kg) received standard normothermic CPB. Sagittal sinus and portal vein oxygen saturations and blood gases were measured at 30, 60, 90, and 120 min of bypass. Although the venous reservoir oxygen saturation remained unchanged during 2 h of bypass, sagittal sinus saturation and pH decreased significantly (66% ± 3.3% to 33% ± 2.2% and 7.38 ± 0.04 to 7.23 ± 0.05, respectively). Likewise in the portal vein, oxygen saturation and pH also decreased (82% ± 2.4% to 59.3% ± 3.9% and 7.39 ± 0.03 to 7.27 ± 0.06, respectively). We conclude that profound regional venous desaturation and progressive regional acidemia may go undetected even when a standard pump flow rate of 100 mL · kg-1 · min- 1 is used and mixed venous oxygen saturation is normal.
AB - Mixed venous oxygen saturation is generally accepted as an indicator of adequacy of systemic oxygen delivery; however, cardiopulmonary bypass (CPB) may alter this relationship. Major postoperative complications potentially secondary to inadequate oxygen delivery during CPB indicate that mixed venous oxygen saturation may not detect regional venous desaturation during CPB. We therefore tested the hypothesis that mixed venous oxygen saturation and pH did not predict regional venous oxygen saturations and pH during 2 h of bypass in a swine model. Six immature swine (27-34 kg) received standard normothermic CPB. Sagittal sinus and portal vein oxygen saturations and blood gases were measured at 30, 60, 90, and 120 min of bypass. Although the venous reservoir oxygen saturation remained unchanged during 2 h of bypass, sagittal sinus saturation and pH decreased significantly (66% ± 3.3% to 33% ± 2.2% and 7.38 ± 0.04 to 7.23 ± 0.05, respectively). Likewise in the portal vein, oxygen saturation and pH also decreased (82% ± 2.4% to 59.3% ± 3.9% and 7.39 ± 0.03 to 7.27 ± 0.06, respectively). We conclude that profound regional venous desaturation and progressive regional acidemia may go undetected even when a standard pump flow rate of 100 mL · kg-1 · min- 1 is used and mixed venous oxygen saturation is normal.
UR - http://www.scopus.com/inward/record.url?scp=0028911113&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0028911113&partnerID=8YFLogxK
U2 - 10.1097/00000539-199503000-00006
DO - 10.1097/00000539-199503000-00006
M3 - Article
C2 - 7864409
AN - SCOPUS:0028911113
SN - 0003-2999
VL - 80
SP - 466
EP - 472
JO - Anesthesia and Analgesia
JF - Anesthesia and Analgesia
IS - 3
ER -