MultiContrast Delayed Enhancement (MCODE) improves detection of subendocardial myocardial infarction by late gadolinium enhancement cardiovascular magnetic resonance: A clinical validation study

W. Patricia Bandettini, Peter Kellman, Christine Mancini, Oscar Julian Booker, Sujethra Vasu, Steve W. Leung, Joel R. Wilson, Sujata M. Shanbhag, Marcus Y. Chen, Andrew E. Arai

Research output: Contribution to journalArticlepeer-review

388 Scopus citations

Abstract

Background: Myocardial infarction (MI) documented by late gadolinium enhancement (LGE) has clinical and prognostic importance, but its detection is sometimes compromised by poor contrast between blood and MI. MultiContrast Delayed Enhancement (MCODE) is a technique that helps discriminate subendocardial MI from blood pool by simultaneously providing a T2-weighted image with a PSIR (phase sensitive inversion recovery) LGE image. In this clinical validation study, our goal was to prospectively compare standard LGE imaging to MCODE in the detection of MI. Methods. Imaging was performed on a 1.5 T scanner on patients referred for CMR including a LGE study. Prospective comparisons between MCODE and standard PSIR LGE imaging were done by targeted, repeat imaging of slice locations. Clinical data were used to determine MI status. Images at each of multiple time points were read on separate days and categorized as to whether or not MI was present and whether an infarction was transmural or subendocardial. The extent of infarction was scored on a sector-by-sector basis. Results: Seventy-three patients were imaged with the specified protocol. The majority were referred for vasodilator perfusion exams and viability assessment (37 ischemia assessment, 12 acute MI, 10 chronic MI, 12 other diagnoses). Forty-six patients had a final diagnosis of MI (30 subendocardial and 16 transmural). MCODE had similar specificity compared to LGE at all time points but demonstrated better sensitivity compared to LGE performed early and immediately before and after the MCODE (p = 0.008 and 0.02 respectively). Conventional LGE only missed cases of subendocardial MI. Both LGE and MCODE identified all transmural MI. Based on clinical determination of MI, MCODE had three false positive MI's; LGE had two false positive MI's including two of the three MCODE false positives. On a per sector basis, MCODE identified more infarcted sectors compared to LGE performed immediately prior to MCODE (p < 0.001). Conclusion: While both PSIR LGE and MCODE were good in identifying MI, MCODE demonstrated more subendocardial MI's than LGE and identified a larger number of infarcted sectors. The simultaneous acquisition of T1 and T2-weighted images improved differentiation of blood pool from enhanced subendocardial MI.

Original languageEnglish
Article number83
JournalJournal of Cardiovascular Magnetic Resonance
Volume14
Issue number1
DOIs
StatePublished - 2012

Bibliographical note

Funding Information:
Supported by the intramural program, National Heart, Lung and Blood Institute, National Institutes of Health.

Funding

Supported by the intramural program, National Heart, Lung and Blood Institute, National Institutes of Health.

FundersFunder number
National Institutes of Health (NIH)
National Heart, Lung, and Blood Institute (NHLBI)ZIAHL004607

    Keywords

    • Cardiovascular magnetic resonance
    • Late gadolinium enhancement
    • MultiContrast Delayed Enhancement
    • Myocardial infarction

    ASJC Scopus subject areas

    • Radiological and Ultrasound Technology
    • Radiology Nuclear Medicine and imaging
    • Cardiology and Cardiovascular Medicine

    Fingerprint

    Dive into the research topics of 'MultiContrast Delayed Enhancement (MCODE) improves detection of subendocardial myocardial infarction by late gadolinium enhancement cardiovascular magnetic resonance: A clinical validation study'. Together they form a unique fingerprint.

    Cite this