Abstract
Ultrasound imaging is a clinically feasible method for assessing muscle size and quality, but manual processing is time-consuming and difficult to scale. Existing artificial intelligence (AI) models measure muscle cross-sectional area, but they do not include assessments of muscle quality or account for the influence of subcutaneous adipose tissue thickness on echo intensity measurements. We developed an open-source AI model to accurately segment the vastus lateralis and subcutaneous adipose tissue in B-mode images for automating measurements of muscle size and quality. The model was trained on 612 ultrasound images from 44 participants who had anterior cruciate ligament reconstruction. Model generalizability was evaluated on a test set of 50 images from 14 unique participants. A U-Net architecture with ResNet50 backbone was used for segmentation. Performance was assessed using the Dice coefficient and Intersection over Union (IoU). Agreement between model predictions and manual measurements was evaluated using intraclass correlation coefficients (ICCs), R² values and standard errors of measurement (SEM). Dice coefficients were 0.9095 and 0.9654 for subcutaneous adipose tissue and vastus lateralis segmentation, respectively. Excellent agreement was observed between model predictions and manual measurements for cross-sectional area (ICC = 0.986), echo intensity (ICC = 0.991) and subcutaneous adipose tissue thickness (ICC = 0.996). The model demonstrated high reliability with low SEM values for clinical measurements (cross-sectional area: 1.15 cm², echo intensity: 1.28–1.78 a.u.). We developed an open-source AI model that accurately segments the vastus lateralis and subcutaneous adipose tissue in B-mode ultrasound images, enabling automated measurements of muscle size and quality.
| Original language | English |
|---|---|
| Pages (from-to) | 2276-2280 |
| Number of pages | 5 |
| Journal | Ultrasound in Medicine and Biology |
| Volume | 51 |
| Issue number | 12 |
| DOIs | |
| State | Published - Dec 2025 |
Bibliographical note
Publisher Copyright:© 2025 World Federation for Ultrasound in Medicine and Biology.
Funding
This project was supported in part by the National Institute of Arthritis and Musculoskeletal and Skin Diseases of the National Institute of Health under grants R00-AR081367 , R01-AR078316 , K23-AR079583 , and R01-AR072061 . Additional support was provided by the AIMS - Artificial intelligence in Medicine Alliance of the University of Kentucky and by the NIH National Center for Advancing Translational Sciences through grant number UL1TR001998 .
| Funders | Funder number |
|---|---|
| African Institute for Mathematical Sciences | |
| National Institute of Arthritis and Musculoskeletal and Skin Diseases | |
| National Center for Advancing Translational Sciences | UL1TR001998 |
| National Institutes of Health | R01-AR078316, R00-AR081367, K23-AR079583, R01-AR072061 |
Keywords
- Deep learning
- Echo intensity
- Muscle quality
- Open-source
- Semantic segmentation
- Ultrasound
ASJC Scopus subject areas
- Biophysics
- Radiological and Ultrasound Technology
- Acoustics and Ultrasonics
Fingerprint
Dive into the research topics of 'Open-Source AI for Vastus Lateralis and Adipose Tissue Segmentation to Assess Muscle Size and Quality'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver