Abstract
To evaluate the feasibility of intravascular retrieval of chronic foreign bodies, we retrospectively reviewed an 8 year experience (1993-2001) of percutaneous retrieval of chronically retained intravascular foreign bodies (n = 6). In 6 of 6 cases (4 catheter fragments, 2 guidewires), 5-90 days elapsed before retrieval via the femoral or internal jugular vein. Under fluoroscopy, we determined the foreign body's course, position and size. A guidewire was advanced through a multipurpose catheter to the foreign body. The multipurpose catheter was replaced with a gooseneck snare catheter and the snare advanced to grasp and remove the foreign body. Percutaneous retrieval was successful in all 6 cases. One patient experienced mild hemoptysis, which resolved within 24 hr of observation. No patient experienced long-term sequelae. Given the potential life-threatening complications from intravascular foreign bodies and the low complication rate from percutaneous retrieval, we recommend extraction of the foreign body even if it is asymptomatic in the chronic setting (> 24 hr).
Original language | English |
---|---|
Pages (from-to) | 440-442 |
Number of pages | 3 |
Journal | CardioVascular and Interventional Radiology |
Volume | 26 |
Issue number | 5 |
DOIs | |
State | Published - 2003 |
Keywords
- Catheters and catheterization
- Complications
- Foreign body embolization
- Guidewire
- Interventional procedures
ASJC Scopus subject areas
- Radiology Nuclear Medicine and imaging
- Cardiology and Cardiovascular Medicine