T1 - Polarized light based scheme to monitor column performance in a continuous foam fractionation column
AU - Swamy, Janakiraman N.
AU - Crofcheck, Czarena L.
AU - Mengüç, MP P.
PY - 2010/4/15
Y1 - 2010/4/15
N2 - Background: A polarized light scattering technique was used to monitor the performance of a continuously operated foam fractionation process. The S11 and S12 parameters, elements of the light scattering matrix, combined together (S11+S12) have been correlated with the bubble size and liquid content for the case of a freely draining foam. The performance of a foam fractionation column is known to have a strong dependence on the bubble size distribution and liquid hold up in foam. In this study the enrichment is used as a metric, representative of foam properties and column performance, and correlated to the S11+S12 parameter.Results: Three different superficial gas velocities (6.9, 7.5, and 10.6 cm/min) and four different pH values (4.8, 5.5, 6.5, and 7.5) are tested for the foam fractionation of a dilute solution of bovine serum albumin (0.1 mg/ml). As a result, at scattering angle of 125° the magnitude of S11+S12 is higher as the pH increases. When the bubble sizes are small with a larger liquid content, the foam is strongly back scattering resulting in lower values of S11+S12 (at 125°) at pH = 4.8. The light scattering data and the enrichment values are measured over a period of 90 minutes and correlated using a linear model. The predictive power of the model was found to be statistically significant.Conclusion: The time average S11+S12 shows a direct proportionality with the enrichment value, indicating that polarized light should be a valuable technique for monitoring foam fractionation columns. Additional knowledge of the nature of dependence between foam properties and S11+S12 combined with models relating the enrichment to the bubble size and liquid hold up is needed to develop an accurate diagnostics tool for monitoring enrichment utilizing S11+S12 measurements.
AB - Background: A polarized light scattering technique was used to monitor the performance of a continuously operated foam fractionation process. The S11 and S12 parameters, elements of the light scattering matrix, combined together (S11+S12) have been correlated with the bubble size and liquid content for the case of a freely draining foam. The performance of a foam fractionation column is known to have a strong dependence on the bubble size distribution and liquid hold up in foam. In this study the enrichment is used as a metric, representative of foam properties and column performance, and correlated to the S11+S12 parameter.Results: Three different superficial gas velocities (6.9, 7.5, and 10.6 cm/min) and four different pH values (4.8, 5.5, 6.5, and 7.5) are tested for the foam fractionation of a dilute solution of bovine serum albumin (0.1 mg/ml). As a result, at scattering angle of 125° the magnitude of S11+S12 is higher as the pH increases. When the bubble sizes are small with a larger liquid content, the foam is strongly back scattering resulting in lower values of S11+S12 (at 125°) at pH = 4.8. The light scattering data and the enrichment values are measured over a period of 90 minutes and correlated using a linear model. The predictive power of the model was found to be statistically significant.Conclusion: The time average S11+S12 shows a direct proportionality with the enrichment value, indicating that polarized light should be a valuable technique for monitoring foam fractionation columns. Additional knowledge of the nature of dependence between foam properties and S11+S12 combined with models relating the enrichment to the bubble size and liquid hold up is needed to develop an accurate diagnostics tool for monitoring enrichment utilizing S11+S12 measurements.
UR - http://www.scopus.com/inward/record.url?scp=77950848960&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77950848960&partnerID=8YFLogxK
U2 - 10.1186/1754-1611-4-5
DO - 10.1186/1754-1611-4-5
M3 - Article
C2 - 20398336
AN - SCOPUS:77950848960
SN - 1754-1611
VL - 4
JO - Journal of Biological Engineering
JF - Journal of Biological Engineering
M1 - 5
ER -