Skip to main navigation Skip to search Skip to main content

Preoperative ultrasound is not useful for identifying nodal metastasis in melanoma patients undergoing sentinel node biopsy: Preoperative ultrasound in clinically node-negative melanoma

  • Christy Y. Chai
  • , Jonathan S. Zager
  • , Margaret M. Szabunio
  • , Suroosh S. Marzban
  • , Alec Chau
  • , Robert M. Rossi
  • , Vernon K. Sondak

Research output: Contribution to journalArticlepeer-review

33 Scopus citations

Abstract

Background. Sentinel lymph node biopsy (SLNB) is widely used in melanoma. Identifying nodal involvement preoperatively by high-resolution ultrasound may offer less invasive staging. This study assessed feasibility and staging results of clinically targeted ultrasound (before lymphoscintigraphy) compared to SLNB. Methods. From 2005 to 2009, a total of 325 patients with melanoma underwent ultrasound before SLNB. We reviewed demographics and histopathologic characteristics, then compared ultrasound and SLNB results. Sensitivity, specificity, and positive and negative predictive value were determined. Results. A total of 325 patients were included, 58% men and 42% women with a median age of 58 (range 18-86) years. A total of 471 basins were examined with ultrasound. Only six patients (1.8%) avoided SLNB by undergoing ultrasound-guided fine-needle aspiration of involved nodes, then therapeutic lymphadenectomy. Sixty-five patients (20.4%) had 69 SLNB positive nodal basins; 17 nodal basins from 15 patients with positive ultrasounds were considered truly positive. Forty-five SLNB positive basins had negative ultrasounds (falsely negative). Seven node-positive basins did not undergo ultrasound because of unpredicted drainage. A total of 253 patients with negative SLNBs had negative ultrasounds in 240 nodal basins (truly negative) but falsely positive ultrasounds occurred in 40 basins. Overall, sensitivity of ultrasound was 33.8%, specificity 85.7%, positive predictive value 36.5%, and negative predictive value 84.2%. Sensitivity and specificity improved somewhat with increasing Breslow depth. Sensitivity was highest for the neck, but specificity was highest for the groin. Conclusions. Routine preoperative ultrasound in clinically node-negative melanoma is impractical because of its low sensitivity. Selected patients with thick or ulcerated lesions may benefit. Because of variable lymphatic drainage patterns, preoperative ultrasound without lymphoscintigraphic localization will provide incomplete evaluation in many cases.

Original languageEnglish
Pages (from-to)1100-1106
Number of pages7
JournalAnnals of Surgical Oncology
Volume19
Issue number4
DOIs
StatePublished - Apr 2012

Funding

FundersFunder number
National Childhood Cancer Registry – National Cancer InstituteP30CA076292

    ASJC Scopus subject areas

    • Surgery
    • Oncology

    Fingerprint

    Dive into the research topics of 'Preoperative ultrasound is not useful for identifying nodal metastasis in melanoma patients undergoing sentinel node biopsy: Preoperative ultrasound in clinically node-negative melanoma'. Together they form a unique fingerprint.

    Cite this