Skip to main navigation Skip to search Skip to main content

Reliability and repeatability of cone density measurements in patients with congenital achromatopsia

  • Mortada A. Abozaid
  • , Christopher S. Langlo
  • , Adam M. Dubis
  • , Michel Michaelides
  • , Sergey Tarima
  • , Joseph Carroll

Research output: Chapter in Book/Report/Conference proceedingChapterpeer-review

46 Scopus citations

Abstract

Adaptive optics scanning light ophthalmoscopy (AOSLO) allows noninvasive assessment of the cone photoreceptor mosaic. Confocal AOSLO imaging of patients with achromatopsia (ACHM) reveals an altered reflectivity of the remaining cone structure, making identification of the cells more challenging than in normal retinas. Recently, a “split-detector” AOSLO imaging method was shown to enable direct visualization of cone inner segments in patients with ACHM. Several studies have demonstrated gene replacement therapy effective in restoring cone function in animal models of ACHM and human trials have on the horizon, making the ability to reliably assess cone structure increasingly important. Here we sought to examine whether absolute estimates of cone density obtained from split-detector and confocal AOSLO images differed from one another and whether the inter- and intra-observer reliability is significantly different between these modes. These findings provide an important foundation for evaluating the role of these images as tools to assess the efficacy of future gene therapy trials.

Original languageEnglish
Title of host publicationAdvances in Experimental Medicine and Biology
Pages277-283
Number of pages7
DOIs
StatePublished - Oct 1 2016

Publication series

NameAdvances in Experimental Medicine and Biology
Volume854
ISSN (Print)0065-2598
ISSN (Electronic)2214-8019

Bibliographical note

Publisher Copyright:
© Springer International Publishing Switzerland 2016.

Funding

The work was supported by grants from the The Wellcome Trust [099173/Z/12/Z], National Institute for Health Research Biomedical Research Centre at Moorfields Eye Hospital National Health Service Foundation Trust and UCL Institute of Ophthalmology, NIH grants R01EY017607, R24EY022023, P30EY001931, C06RR016511, & UL1TR000055, Fight For Sight (UK), Moorfields Eye Hospital Special Trustees, the Foundation Fighting Blindness (USA), RP Fighting Blindness, an unrestricted departmental grant from Research to Prevent Blindness (RPB). Dr. Michaelides is supported by an FFB Career Development Award.

FundersFunder number
Moorfields Eye Hospital Special Trustees
National Institute for Health Research Biomedical Research Centre at Moorfields Eye Hospital National Health Service Foundation Trust
RP Fighting Blindness
National Institutes of Health (NIH)UL1TR000055, R24EY022023, P30EY001931, C06RR016511
National Eye Institute (NEI)R01EY017607
Foundation Fighting Blindness
Research to Prevent Blindness
Wellcome Trust099173/Z/12/Z
Fight for Sight Inc
UCL Institute of Ophthalmology, University College London

    Keywords

    • Achromatopsia
    • Adaptive optics
    • Cone photoreceptor
    • Reliability
    • Repeatability

    ASJC Scopus subject areas

    • General Biochemistry, Genetics and Molecular Biology

    Fingerprint

    Dive into the research topics of 'Reliability and repeatability of cone density measurements in patients with congenital achromatopsia'. Together they form a unique fingerprint.

    Cite this