TY - JOUR
T1 - Reliability of 3-Dimensional Measures of Single-Leg Cross Drop Landing Across 3 Different Institutions
T2 - Implications for Multicenter Biomechanical and Epidemiological Research on ACL Injury Prevention
AU - DiCesare, Christopher A.
AU - Bates, Nathaniel A.
AU - Barber Foss, Kim D.
AU - Thomas, Staci M.
AU - Wordeman, Samuel C.
AU - Sugimoto, Dai
AU - Roewer, Benjamin D.
AU - Medina McKeon, Jennifer M.
AU - Di Stasi, Stephanie
AU - Noehren, Brian W.
AU - Ford, Kevin R.
AU - Kiefer, Adam W.
N1 - Publisher Copyright:
© 2015, © The Author(s) 2015.
PY - 2015/12/30
Y1 - 2015/12/30
N2 - Background: Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. Purpose: To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Study Design: Controlled laboratory study. Methods: Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Results: Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Conclusion: Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Clinical Relevance: Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated.
AB - Background: Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. Purpose: To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Study Design: Controlled laboratory study. Methods: Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Results: Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Conclusion: Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Clinical Relevance: Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated.
KW - anterior cruciate ligament
KW - biomechanics
KW - epidemiology
KW - multicenter
UR - http://www.scopus.com/inward/record.url?scp=84978969881&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84978969881&partnerID=8YFLogxK
U2 - 10.1177/2325967115617905
DO - 10.1177/2325967115617905
M3 - Article
AN - SCOPUS:84978969881
VL - 3
JO - Orthopaedic Journal of Sports Medicine
JF - Orthopaedic Journal of Sports Medicine
IS - 12
ER -