T1 - Squeeze me if you can
T2 - Variability in force requirements to extract a drop from common glaucoma bottles
AU - Moore, Daniel B.
AU - Hammer, Jon D.
AU - Akhtari, Roozbeh
AU - Beck, Judy
AU - Sanders, Sheila
AU - Kryscio, Richard J.
N1 - Publisher Copyright:
© 2016 Wolters Kluwer Health, Inc.
PY - 2016
Y1 - 2016
N2 - Purpose: To determine the force requirements to dispense a single drop from commonly prescribed brand and generic topical glaucoma medications and correlate these findings with pinch strength in a representative patient population. Patients and Methods: Four bottles of each medication were tested: 2 in the vertical and 2 in the horizontal orientation. Bottles were housed in a customized force gauge apparatus designed to mimic ballpoint fingertip contact with a bottle tip. For all bottles, each of the first 10 dispensed drops was tested and then tests were performed in increments of 10 until the bottle was empty. For each tested drop, the maximum force and displacement were electronically measured. Concurrently, maximum pinch strength was measured on consecutive glaucoma patients. Results: A total of 84 bottles from 21 bottle designs were tested. There was significant variability across the designs, with roughly a 7-fold (0.67 to 4.49 kgf) and 4-fold (0.81 to 3.00 kgf) difference in force requirements in the vertical and horizontal positions, respectively. Of 53 enrolled patients in the glaucoma clinic, the mean pinch strength was 5.05 (range, 1.23 to 10.4 kgf) and 4.82 (range, 1.47 to 10.67 kgf) kgf for the right and left hands, respectively. Conclusions: There is statistically significant variability in the force required to squeeze a drop from common glaucoma medications, and a representative sampling of clinic patients suggests that many likely struggle with the force requirements of several bottle designs. These data further support standardization of topical glaucoma drug delivery and design.
AB - Purpose: To determine the force requirements to dispense a single drop from commonly prescribed brand and generic topical glaucoma medications and correlate these findings with pinch strength in a representative patient population. Patients and Methods: Four bottles of each medication were tested: 2 in the vertical and 2 in the horizontal orientation. Bottles were housed in a customized force gauge apparatus designed to mimic ballpoint fingertip contact with a bottle tip. For all bottles, each of the first 10 dispensed drops was tested and then tests were performed in increments of 10 until the bottle was empty. For each tested drop, the maximum force and displacement were electronically measured. Concurrently, maximum pinch strength was measured on consecutive glaucoma patients. Results: A total of 84 bottles from 21 bottle designs were tested. There was significant variability across the designs, with roughly a 7-fold (0.67 to 4.49 kgf) and 4-fold (0.81 to 3.00 kgf) difference in force requirements in the vertical and horizontal positions, respectively. Of 53 enrolled patients in the glaucoma clinic, the mean pinch strength was 5.05 (range, 1.23 to 10.4 kgf) and 4.82 (range, 1.47 to 10.67 kgf) kgf for the right and left hands, respectively. Conclusions: There is statistically significant variability in the force required to squeeze a drop from common glaucoma medications, and a representative sampling of clinic patients suggests that many likely struggle with the force requirements of several bottle designs. These data further support standardization of topical glaucoma drug delivery and design.
KW - Eyedrop
KW - Glaucoma medication
KW - Pharmacology
KW - Pinch strength
UR - http://www.scopus.com/inward/record.url?scp=84983347959&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84983347959&partnerID=8YFLogxK
U2 - 10.1097/IJG.0000000000000506
DO - 10.1097/IJG.0000000000000506
M3 - Article
C2 - 27552516
AN - SCOPUS:84983347959
SN - 1057-0829
VL - 25
SP - 780
EP - 784
JO - Journal of Glaucoma
JF - Journal of Glaucoma
IS - 9
ER -