TY - JOUR
T1 - Stability of infliximab in polyvinyl chloride bags
AU - Ikeda, Ryuji
AU - Vermeulen, Lee C.
AU - Lau, Elim
AU - Jiang, Zhisheng
AU - Saha, Sumona
AU - Reichelderfer, Mark
AU - Kolesar, Jil M.
PY - 2012/9/1
Y1 - 2012/9/1
N2 - Purpose. The stability of prepared infusions of the tumor necrosis factor (TNF)-α agent infliximab after storage for up to two weeks was investigated. Methods. To determine the feasibility of liberalized expiration dating of infliximab (current recommendations call for the infusion of prepared doses within three hours), the stability of diluted infliximab stored in polyvinyl chloride (PVC) bags at 4°C for up to 14 days was evaluated. A known quantity of TNF-a was combined with infliximab test samples in PVC bags for one hour; immediately after the reaction period and after 7 and 14 days of storage, the residual amount of TNF-α (an indirect measure of the drug's biological activity) was analyzed via a validated enzyme-linked immunosorbent assay (ELISA). Results. The mean ± S.D. amount of TNF-α consumed by infliximab was calculated to be 24.5 ± 5.6 pg/mL at baseline, 29.0 ± 4.4 pg/mL at 7 days, and 24.8 ± 17.3 pg/ mL at 14 days. At all evaluated time points, ELISA results indicated that 19-24% of the original TNF-α had been consumed by infliximab (mean ± S.D. consumption: 19.6% ± 4.5% at baseline, 23.2% ± 3.5% at 7 days, and 19.8% ± 13.8% at 14 days). Conclusion. Infliximab, when prepared at a concentration of 400 μg/mL in 0.9% sodium chloride injection, incurred no loss of biological activity when stored for up to 14 days at 4°C in PVC bags. Changing in- fliximab preparation practices may improve clinic efficiency by reducing patient dissatisfaction with long wait times for infusions and avoiding costly waste.
AB - Purpose. The stability of prepared infusions of the tumor necrosis factor (TNF)-α agent infliximab after storage for up to two weeks was investigated. Methods. To determine the feasibility of liberalized expiration dating of infliximab (current recommendations call for the infusion of prepared doses within three hours), the stability of diluted infliximab stored in polyvinyl chloride (PVC) bags at 4°C for up to 14 days was evaluated. A known quantity of TNF-a was combined with infliximab test samples in PVC bags for one hour; immediately after the reaction period and after 7 and 14 days of storage, the residual amount of TNF-α (an indirect measure of the drug's biological activity) was analyzed via a validated enzyme-linked immunosorbent assay (ELISA). Results. The mean ± S.D. amount of TNF-α consumed by infliximab was calculated to be 24.5 ± 5.6 pg/mL at baseline, 29.0 ± 4.4 pg/mL at 7 days, and 24.8 ± 17.3 pg/ mL at 14 days. At all evaluated time points, ELISA results indicated that 19-24% of the original TNF-α had been consumed by infliximab (mean ± S.D. consumption: 19.6% ± 4.5% at baseline, 23.2% ± 3.5% at 7 days, and 19.8% ± 13.8% at 14 days). Conclusion. Infliximab, when prepared at a concentration of 400 μg/mL in 0.9% sodium chloride injection, incurred no loss of biological activity when stored for up to 14 days at 4°C in PVC bags. Changing in- fliximab preparation practices may improve clinic efficiency by reducing patient dissatisfaction with long wait times for infusions and avoiding costly waste.
UR - http://www.scopus.com/inward/record.url?scp=84865955800&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84865955800&partnerID=8YFLogxK
U2 - 10.2146/ajhp100116
DO - 10.2146/ajhp100116
M3 - Article
C2 - 22899746
AN - SCOPUS:84865955800
SN - 1079-2082
VL - 69
SP - 1509
EP - 1512
JO - American Journal of Health-System Pharmacy
JF - American Journal of Health-System Pharmacy
IS - 17
ER -