TY - JOUR
T1 - Steady-state pleural fluid flow and pressure and the effects of lung buoyancy
AU - Haber, R.
AU - Grotberg, J. B.
AU - Glucksberg, M. R.
AU - Miserocchi, G.
AU - Venturoli, D.
AU - Del Fabbro, M.
AU - Waters, C. M.
PY - 2001
Y1 - 2001
N2 - Both theoretical and experimental studies of pleural fluid dynamics and lung buoyancy during steady-state, apneic conditions are presented. The theory shows that steady-state, top-to-bottom pleural-liquid flow creates a pressure distribution that opposes lung buoyancy. These two forces may balance, permitting dynamic lung floating, but when they do not, pleural-pleural contact is required. The animal experiments examine pleural-liquid pressure distributions in response to simulated reduced gravity, achieved by lung inflation with perfluorocarbon liquid as compared to air. The resulting decrease in lung buoyancy modifies the force balance in the pleural fluid, which is reflected in its vertical pressure gradient. The data and model show that the decrease in buoyancy with perfluorocarbon inflation causes the vertical pressure gradient to approach hydrostatic. In the microgravity analogue, the pleural pressures would be toward a more uniform distribution, consistent with ventilation studies during space flight. The pleural liquid turnover predicted by the model is computed and found to be comparable to experimental values from the literature. The model provides the flow field, which can be used to develop a full transport theory for molecular and cellular constituents that are found in pleural fluid.
AB - Both theoretical and experimental studies of pleural fluid dynamics and lung buoyancy during steady-state, apneic conditions are presented. The theory shows that steady-state, top-to-bottom pleural-liquid flow creates a pressure distribution that opposes lung buoyancy. These two forces may balance, permitting dynamic lung floating, but when they do not, pleural-pleural contact is required. The animal experiments examine pleural-liquid pressure distributions in response to simulated reduced gravity, achieved by lung inflation with perfluorocarbon liquid as compared to air. The resulting decrease in lung buoyancy modifies the force balance in the pleural fluid, which is reflected in its vertical pressure gradient. The data and model show that the decrease in buoyancy with perfluorocarbon inflation causes the vertical pressure gradient to approach hydrostatic. In the microgravity analogue, the pleural pressures would be toward a more uniform distribution, consistent with ventilation studies during space flight. The pleural liquid turnover predicted by the model is computed and found to be comparable to experimental values from the literature. The model provides the flow field, which can be used to develop a full transport theory for molecular and cellular constituents that are found in pleural fluid.
UR - http://www.scopus.com/inward/record.url?scp=0034790954&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034790954&partnerID=8YFLogxK
U2 - 10.1115/1.1392317
DO - 10.1115/1.1392317
M3 - Article
C2 - 11601734
AN - SCOPUS:0034790954
SN - 0148-0731
VL - 123
SP - 485
EP - 492
JO - Journal of Biomechanical Engineering
JF - Journal of Biomechanical Engineering
IS - 5
ER -