TY - JOUR
T1 - The computer-generated bone marrow subtraction image
T2 - A valuable adjunct to combined In-111 WBC/Tc-99m in sulfur colloid scintigraphy for musculoskeletal infection
AU - Achong, D. M.
AU - Oates, E.
PY - 1994
Y1 - 1994
N2 - In-111 WBC scintigraphy supplemented by visual comparison with concurrent Tc-99m SC bone marrow imaging is used to identify infection within the marrow-containing skeleton. This retrospective study demonstrates the value of the computer-generated WBC/SC bone marrow subtraction image. Thirty-one patients with various conditions (postsurgery with or without orthopedic hardware, bacteremia with persistent fever, joint arthroplasty, and miscellaneous) underwent combined WBC/SC with bone marrow subtraction imaging. Infection was present in 21 of 36 possible sites (14 osseous, 7 soft tissue; 8 acute, 13 chronic). The bone marrow subtraction image identified two of these sites, which were not appreciated by visual inspection. The sensitivity, specificity, and accuracy for bone marrow subtraction were 95%, 93%, and 94%, respectively, as compared to 86%, 93%, and 89%, respectively, for the visual assessment of WBC and SC images. Computer-assisted subtraction imaging improves overall accuracy and enhances diagnostic certainty of combined WBC/SC scintigraphy for infection in the marrow-containing skeleton.
AB - In-111 WBC scintigraphy supplemented by visual comparison with concurrent Tc-99m SC bone marrow imaging is used to identify infection within the marrow-containing skeleton. This retrospective study demonstrates the value of the computer-generated WBC/SC bone marrow subtraction image. Thirty-one patients with various conditions (postsurgery with or without orthopedic hardware, bacteremia with persistent fever, joint arthroplasty, and miscellaneous) underwent combined WBC/SC with bone marrow subtraction imaging. Infection was present in 21 of 36 possible sites (14 osseous, 7 soft tissue; 8 acute, 13 chronic). The bone marrow subtraction image identified two of these sites, which were not appreciated by visual inspection. The sensitivity, specificity, and accuracy for bone marrow subtraction were 95%, 93%, and 94%, respectively, as compared to 86%, 93%, and 89%, respectively, for the visual assessment of WBC and SC images. Computer-assisted subtraction imaging improves overall accuracy and enhances diagnostic certainty of combined WBC/SC scintigraphy for infection in the marrow-containing skeleton.
UR - http://www.scopus.com/inward/record.url?scp=0028212979&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0028212979&partnerID=8YFLogxK
U2 - 10.1097/00003072-199403000-00004
DO - 10.1097/00003072-199403000-00004
M3 - Article
C2 - 8033465
AN - SCOPUS:0028212979
SN - 0363-9762
VL - 19
SP - 188
EP - 193
JO - Clinical Nuclear Medicine
JF - Clinical Nuclear Medicine
IS - 3
ER -