Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

A novel method for the rapid detection of post-translationally modified visinin-like protein 1 in rat models of brain injury

Producción científica: Article › revisión exhaustiva

11 Citas (Scopus)

Resumen

Background: Although elevated serum levels of visinin-like protein 1 (VILIP-1), a neuron-specific calcium sensor protein, are associated with ischaemic stroke, only a single study has evaluated VILIP-1 as a biomarker of traumatic brain injury (TBI). The current proof-of-concept study was designed to determine whether serum VILIP-1 levels increase post-injury in a well-characterized rat unilateral cortical contusion model. Methods: Lateral flow devices (LFDs) rapidly (< 20 min) detected trace serum levels (pg/mL) of VILIP-1 in a small input sample volume (10 µL). Temporal profiles of serum levels at baseline and post-injury were measured in male Sprague Dawley rats subjected to very mild-, mild unilateral-cortical contusion, or naïve surgery and in male Sprague Dawley rats following a diffuse TBI or sham surgery. Results: Mean serum levels were significantly elevated by 0.5 h post-injury and remained so throughout the temporal profile compared with baseline in very mild and mild unilateral contusions but not in naïve surgeries. Serum levels were also elevated in a small cohort of animals subjected to a diffuse TBI injury. Conclusions: Overall, the current study demonstrates that the novel LFD is a reliable and rapid point-of-care diagnostic for the detection and quantification of serum levels of UB-VILIP-1 in a clinically relevant time frame.

Idioma originalEnglish
Páginas (desde-hasta)363-380
Número de páginas18
PublicaciónBrain Injury
Volumen32
N.º3
DOI
EstadoPublished - feb 23 2018

Nota bibliográfica

Publisher Copyright:
© 2017 Taylor & Francis Group, LLC.

Financiación

This research was supported by Kentucky Spinal Cord Head Injury Research Trust #13-7 (to MAL). Drs Lovell, Lynn, and Bradley-Whitman hold an equity interest in Fawkes Diagnostics LLC., which has licensed the use of the LFD for detection of VILIP-1 (Patent Number: US 9,482,675 B1).

FinanciadoresNúmero del financiador
National Institute on AgingP30AG028383
Kentucky Spinal Cord and Head Injury Research Trust13-7

    ASJC Scopus subject areas

    • Neuroscience (miscellaneous)
    • Developmental and Educational Psychology
    • Clinical Neurology

    Huella

    Profundice en los temas de investigación de 'A novel method for the rapid detection of post-translationally modified visinin-like protein 1 in rat models of brain injury'. En conjunto forman una huella única.

    Citar esto