Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

A preliminary study of hydrocodone and hydromorphone to oxycodone ratios for distinguishing impurities from independent opioid use

  • Ibrahim Choucair
  • , Cristina Figueroa Villalba
  • , Michael A. Vera
  • , Gina Cassella-Mclane
  • , Thomas J.S. Durant
  • , Joe M. El-Khoury

Producción científica: Articlerevisión exhaustiva

3 Citas (Scopus)

Resumen

Background: Urine drug testing (UDT) monitors prescription compliance and/or drug abuse. However, interpretation of UDT results obtained by liquid chromatography-tandem mass spectrometry (LC-MS-MS) can be complicated by the presence of drug impurities that are detected by highly sensitive methods. Hydrocodone is a drug impurity that can be found as high as 1% in oxycodone pills. Objectives: We evaluated the frequency and concentration of hydrocodone and its metabolite, hydromorphone, in patients taking oxycodone to check if the ratio of hydrocodone or hydromorphone to oxycodone could distinguish between oxycodone only use from those consuming additional opiates. Design & methods: We correlated LC-MS/MS results with medication records of 319 patients with positive oxycodone results over 7 months (4/2021-11/2021). Results: Fifteen of 319 patients with positive oxycodone results were taking oxycodone only. For these 15 patients, the mean ratio of hydrocodone to oxycodone was 0.57% (range 0.05%-3.35%), and the mean ratio of hydromorphone to oxycodone was 0.81% (range 0.18–3.51%). Conclusions: Hydrocodone and/or hydromorphone are detectable in patients taking only oxycodone and can likely be identified as an impurity if their calculated ratio to oxycodone is <1 %. Further validation of the ratios in a larger sample size is recommended.

Idioma originalEnglish
Páginas (desde-hasta)6-10
Número de páginas5
PublicaciónClinical Biochemistry
Volumen112
DOI
EstadoPublished - feb 2023

Nota bibliográfica

Publisher Copyright:
© 2022 The Canadian Society of Clinical Chemists

ODS de las Naciones Unidas