Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Absolute configuration of 2,2′,3,3′,6-pentachlorinatedbiphenyl (PCB 84) atropisomers

  • Xueshu Li
  • , Sean R. Parkin
  • , Hans Joachim Lehmler

Producción científica: Articlerevisión exhaustiva

8 Citas (Scopus)

Resumen

Nineteen polychlorinated biphenyl (PCB) congeners, such as 2,2′,3,3′,6-pentachlorobiphenyl (PCB 84), display axial chirality because they form stable rotational isomers, or atropisomers, that are non-superimposable mirror images of each other. Although chiral PCBs undergo atropselective biotransformation and atropselectively alter biological processes, the absolute structure of only a few PCB atropisomers has been determined experimentally. To help close this knowledge gap, pure PCB 84 atropisomers were obtained by semi-preparative liquid chromatography with two serially connected Nucleodex β-PM columns. The absolute configuration of both atropisomers was determined by X-ray single-crystal diffraction. The PCB 84 atropisomer eluting first and second on the Nucleodex β-PM column correspond to (aR)-(−)-PCB 84 and (aS)-(+)-PCB 84, respectively. Enantioselective gas chromatographic analysis with the β-cyclodextrin-based CP-Chirasil-Dex CB gas chromatography column showed the same elution order as the Nucleodex β-PM column. Based on earlier reports, the atropisomers eluting first and second on the BGB-172 gas chromatography column are (aR)-(−)-PCB 84 and (aS)-(+)-PCB 84, respectively. An inversion of the elution order is observed on the Cyclosil-B gas chromatography and Cellulose-3 liquid chromatography columns. These results advance the interpretation of environmental and human biomonitoring as well as toxicological studies.

Idioma originalEnglish
Páginas (desde-hasta)16402-16410
Número de páginas9
PublicaciónEnvironmental Science and Pollution Research
Volumen25
N.º17
DOI
EstadoPublished - jun 1 2018

Nota bibliográfica

Publisher Copyright:
© 2017, Springer-Verlag Berlin Heidelberg.

Financiación

This work was supported by grants ES05605, ES013661, and ES017425 from the National Institute of Environmental Health Sciences/National Institutes of Health. The X8 Proteum diffractometer was funded by the National Science Foundation (MRI CHE0319176) and by the University of Kentucky (cost share). The content of this manuscript is solely the responsibility of the authors and does not necessarily represent the official views of the National Institute of Environmental Health Sciences/National Institutes of Health or the National Science Foundation.

FinanciadoresNúmero del financiador
National Science Foundation Arctic Social Science ProgramMRI CHE0319176
Foundation for the National Institutes of Health
National Institutes of Health/National Institute of Environmental Health SciencesP42ES013661
University of Kentucky

    ASJC Scopus subject areas

    • Environmental Chemistry
    • Pollution
    • Health, Toxicology and Mutagenesis

    Huella

    Profundice en los temas de investigación de 'Absolute configuration of 2,2′,3,3′,6-pentachlorinatedbiphenyl (PCB 84) atropisomers'. En conjunto forman una huella única.

    Citar esto