Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Acute Effects of Implantable Cardioverter-Defibrillator Shocks on Biomarkers of Myocardial Injury, Apoptosis, Heart Failure, and Systemic Inflammation

  • Jordan Brewster
  • , Travis Sexton
  • , Gary Dhaliwal
  • , Richard Charnigo
  • , Gustavo Morales
  • , Kevin Parrott
  • , Yousef Darrat
  • , John Gurley
  • , Susan Smyth
  • , Claude S. Elayi

Producción científica: Article › revisión exhaustiva

20 Citas (Scopus)

Resumen

Background: Implantable cardioverter-defibrillator (ICD) shocks are potentially associated with myocardial injury, altered hemodynamics, apoptosis, and inflammatory signaling. Their precise cellular impact can be explored after defibrillation testing (DFT) via biomarkers. We evaluated changes in biomarkers after ICD shocks during DFT. Methods: We prospectively enrolled outpatients presenting for first implantation of a cardiac device. Biomarkers indicative of myocardial injury, inflammation, and apoptosis were measured before and after implantation, and compared between patients receiving DFT (DFT+) to those not (DFT−). Results: Sixty-three patients were enrolled, 40 in the DFT+ group and 23 in the DFT− group. Average levels of troponin I, hsCRP, Calprotectin, N-terminal pro B-type natriuretic peptide (NTproBNP), and sFas increased by >50% after cardiac device implantation compared to baseline. Increase in troponin never exceeded the 50-fold upper limit of normal (2 ng/mL). Troponin trended higher in the DFT+ group at 8 hours (median 0.18 ng/mL, interquartile range [IQR] 0.11–0.48) versus the DFT− group (0.10 ng/mL, IQR 0.06–0.28, P = 0.0501); NTproBNP had a similar trend (P = 0.0581). sFas significantly increased in the DFT+ group from baseline (median 4663 pg/mL, IQR 2908–5679) to 24 hours (5039 pg/mL, IQR 3274–6261; P = 0.0338) but not in the DFT− group (P = 0.4705). Conclusion: DFT testing is associated with acutely increased plasma levels of troponin and sFas, a biomarker of apoptosis, along with a trend toward higher NTproBNP.

Idioma originalEnglish
Páginas (desde-hasta)344-352
Número de páginas9
PublicaciónPACE - Pacing and Clinical Electrophysiology
Volumen40
N.º4
DOI
EstadoPublished - abr 2017

Nota bibliográfica

Publisher Copyright:
© 2017 Wiley Periodicals, Inc.

Financiación

This publication was supported by the National Center for Research Resources and the National Center for Advancing Translational Sciences, National Institutes of Health, through Grant UL1TR000117. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.

FinanciadoresNúmero del financiador
National Institutes of Health (NIH)
National Center for Research Resources
National Center for Advancing Translational Sciences (NCATS)UL1TR000117

    ASJC Scopus subject areas

    • Cardiology and Cardiovascular Medicine

    Huella

    Profundice en los temas de investigación de 'Acute Effects of Implantable Cardioverter-Defibrillator Shocks on Biomarkers of Myocardial Injury, Apoptosis, Heart Failure, and Systemic Inflammation'. En conjunto forman una huella única.