Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Adhesion of Biofilms on Titanium Measured by Laser-Induced Spallation

Producción científica: Article › revisión exhaustiva

15 Citas (Scopus)

Resumen

Eradication of established implant-associated and bacterial biofilm-forming infections remains difficult in part because these biofilms remain well-adhered to the implant surface. Few experimental techniques are available to measure macro-scale strength of bacterial biofilm-implant adhesion. We have adapted the laser spallation technique to compare the macro-scale adhesion strength of biofilms formed on titanium. By using a rapid pressure wave (35 ns) to load the interface, we prevent disturbance of the biofilm surface prior to measurement, and preclude the time necessary for the biofilm to respond to and adapt under loading. Biofilms of Streptococcus mutans, a Gram-positive bacterium associated with human dental caries (cavities) were cultured directly on commercially pure titanium within our custom substrate assembly. Growth conditions were varied by adding sucrose to the Todd Hewitt Yeast (THY) broth: THY control, 37.5 mM, 75 mM, 375 mM, and 750 mM sucrose. Multiple locations on each biofilm were loaded using the laser spallation technique. Loading pressure wave amplitude was controlled by adjusting laser fluence, energy per area. Initially, addition of sucrose to the media increased biofilm adhesion to titanium. However, once a saturation concentration of 75 mM sucrose was reached, increasing the sucrose concentration further resulted in a decrease in biofilm adhesion. This study is the first demonstration of the adaptation of the laser spallation technique to measure bacterial biofilm adhesion. Establishment of this macro-scale biofilm adhesion measurement technique opens the door for many biofilm-surface adhesion studies. We anticipate further work in this area towards understanding the complex relationships among bacteria species, environmental factors, surface characteristics, and biofilm adhesion strength.

Idioma originalEnglish
Páginas (desde-hasta)1275-1284
Número de páginas10
PublicaciónExperimental Mechanics
Volumen59
N.º9
DOI
EstadoPublished - nov 1 2019

Nota bibliográfica

Publisher Copyright:
© 2018, Society for Experimental Mechanics.

Financiación

We would like to acknowledge NIH COBRE Phase III pilot funding under number 5P30GM110788-04 to carry out these experiments. SEM images were taken within the Electron Microscopy Center at the University of Kentucky by staff associate Azin Akbari. We thank the Center for Pharmaceutical Research and Innovation (CPRI) for use of bacterial culture equipment. CPRI is supported, in part, by the University of Kentucky College of Pharmacy and Center for Clinical and Translational Science (UL1TR001998). We thank Dr. Larissa Ponomareva for sharing her bacterial culture expertise. We would also like to thank Drs. Craig Miller, Lina Sharab, and Ahmad Kutkut from the University of Kentucky College of Dentistry for their guidance.

FinanciadoresNúmero del financiador
Center for Pharmaceutical Research and Innovation
National Institutes of Health (NIH)
University of Kentucky
University of Kentucky College of Dentistry
University of Kentucky, Center for Clinical and Translational ScienceUL1TR001998
Institute of Infection and Immunity5P30GM110788-04

    ASJC Scopus subject areas

    • Aerospace Engineering
    • Mechanics of Materials
    • Mechanical Engineering

    Huella

    Profundice en los temas de investigación de 'Adhesion of Biofilms on Titanium Measured by Laser-Induced Spallation'. En conjunto forman una huella única.

    Citar esto