Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Application of a new informatics tool for contamination screening in the HIV sequencing laboratory

  • Mark T.W. Ebbert
  • , Melanie A. Mallory
  • , Andrew R. Wilson
  • , Shane K. Dooley
  • , David R. Hillyard

Producción científica: Articlerevisión exhaustiva

7 Citas (Scopus)

Resumen

Background: Current HIV-1 sequencing-based methods for detecting drug resistance-associated mutations are open and susceptible to contamination. Informatic identification of clinical sequences that are nearly identical to one another may indicate specimen-to-specimen contamination or another laboratory-associated issue. Objectives: To design an informatic tool to rapidly identify potential contamination in the clinical laboratory using sequence analysis and to establish reference ranges for sequence variation in the HIV-1 protease and reverse transcriptase regions among a U.S. patient population. Study design: We developed an open-source tool named HIV Contamination Detection (HIVCD). HIVCD was utilized to make pairwise comparisons of nearly 8000 partial HIV-1 pol gene sequences from patients across the United States and to calculate percent identities (PIDs) for each pair. ROC analysis and standard deviations of PID data were used to determine reference ranges for between-patient and within-patient comparisons and to guide selection of a threshold for identifying abnormally high PID between two unrelated sequences. Results: The PID reference range for between-patient comparisons ranged from 83.8 to 95.7% while within-patient comparisons ranged from 96 to 100%. Interestingly, 48% of between-patient sequence pairs with a PID > 96.5 were geographically related. The selected threshold for abnormally high PIDs was 96 (AUC = 0.993, sensitivity = 0.980, specificity = 0.999). During routine use, HIVCD identified a specimen mix-up and the source of contamination of a negative control. Conclusions: In our experience, HIVCD is easily incorporated into laboratory workflow, useful for identifying potential laboratory errors, and contributes to quality testing. This type of analysis should be incorporated into routine laboratory practice.

Idioma originalEnglish
Páginas (desde-hasta)249-253
Número de páginas5
PublicaciónJournal of Clinical Virology
Volumen57
N.º3
DOI
EstadoPublished - jul 2013

Nota bibliográfica

Funding Information:
This research was funded by the ARUP Institute for Clinical and Experimental Pathology . We gratefully acknowledge Maria Erali for assistance with manuscript preparation and Mitchell T. Sears for technical assistance.

Financiación

This research was funded by the ARUP Institute for Clinical and Experimental Pathology . We gratefully acknowledge Maria Erali for assistance with manuscript preparation and Mitchell T. Sears for technical assistance.

Financiadores
ARUP Institute for Clinical and Experimental Pathology

    ODS de las Naciones Unidas

    Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

    1. Good health and well being
      Good health and well being

    ASJC Scopus subject areas

    • Virology
    • Infectious Diseases

    Huella

    Profundice en los temas de investigación de 'Application of a new informatics tool for contamination screening in the HIV sequencing laboratory'. En conjunto forman una huella única.

    Citar esto