Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Blood longitudinal (T 1) and transverse (T 2) relaxation time constants at 11.7 Tesla

  • Ai Ling Lin
  • , Qin Qin
  • , Xia Zhao
  • , Timothy Q. Duong

Producción científica: Articlerevisión exhaustiva

50 Citas (Scopus)

Resumen

Object: The goal of the study was to determine blood T 1 and T 2 values as functions of oxygen saturation (Y), temperature (Temp) and hematocrit (Hct) at an ultrahigh MR field (11.7 T) and explore their impacts on physiological measurements, including cerebral blood flow (CBF), blood volume (CBV) and oxygenation determination. Materials and methods: T 1 and T 2 were simultaneously measured. Temperature was adjusted from 25 to 40°C to determine Temp dependence; Hct of 0.17-0.51 to evaluate Hct dependence at 25 and 37°C; and Y of 40-100% to evaluate Y dependence at 25 and 37°C. Comparisons were made with published data obtained at different magnetic field strengths (B 0). Results: T 1 was positively correlated with Temp, independent of Y, and negatively correlated with Hct. T 2 was negatively correlated with Temp and Hct, but positively correlated with Y, in a non-linear fashion. T 1 increased linearly with B 0, whereas T 2 decreased exponentially with B 0. Conclusion: This study reported blood T 1 and T 2 measurements at 11.7 T for the first time. These blood relaxation data could have implications in numerous functional and physiological MRI studies at 11.7 T.

Idioma originalEnglish
Páginas (desde-hasta)245-249
Número de páginas5
PublicaciónMagnetic Resonance Materials in Physics, Biology and Medicine
Volumen25
N.º3
DOI
EstadoPublished - jun 2012

Nota bibliográfica

Funding Information:
We thank Hsiao-Ying Wey of the Research Imaging Institute and Saaussan Madi of Bruker Biospin for technical support. This work was supported by in part by the NIH (R01EY014211, R01EY018855) and VA MERIT. We are also grateful for the resources and support from NIH/NCRR (S10 RR023038), from the Defense Advanced Research Projects Agency (Comprehensive Facility for Animal Imaging Research (CFAIR), HR0011-07-C-0027), and the Texas Emerging Technology Fund from the Office of the Governor of Texas.

Financiación

We thank Hsiao-Ying Wey of the Research Imaging Institute and Saaussan Madi of Bruker Biospin for technical support. This work was supported by in part by the NIH (R01EY014211, R01EY018855) and VA MERIT. We are also grateful for the resources and support from NIH/NCRR (S10 RR023038), from the Defense Advanced Research Projects Agency (Comprehensive Facility for Animal Imaging Research (CFAIR), HR0011-07-C-0027), and the Texas Emerging Technology Fund from the Office of the Governor of Texas.

FinanciadoresNúmero del financiador
CFAIRHR0011-07-C-0027
Comprehensive Facility for Animal Imaging Research
Office of the Governor of Texas
VA Merit Award
National Institutes of Health (NIH)R01EY014211
National Institutes of Health (NIH)
National Eye Institute/National Institutes of HealthR01EY018855
National Eye Institute/National Institutes of Health
National Center for Research ResourcesS10 RR023038
National Center for Research Resources
Defense Advanced Research Projects Agency
Texas Emerging Technology Fund

    ASJC Scopus subject areas

    • Biophysics
    • Radiological and Ultrasound Technology
    • Radiology Nuclear Medicine and imaging

    Huella

    Profundice en los temas de investigación de 'Blood longitudinal (T 1) and transverse (T 2) relaxation time constants at 11.7 Tesla'. En conjunto forman una huella única.

    Citar esto