Case study of the conversion of tangential- and wall-fired units to low- NO(x) combustion: Impact on fly ash quality

  • James C. Hower
  • , Robert F. Rathbone
  • , Thomas L. Robl
  • , Gerald A. Thomas
  • , Bethel O. Haeberlin
  • , Alan S. Trimble

Producción científica: Article › revisión exhaustiva

45 Citas (Scopus)

Resumen

Conversion of boilers to low-NO(x) combustion can influence fly ash quality in terms of the mount and forms of carbon, the overall fly ash fineness, and the relative amount of glass versus crystalline inorganic phases. All of these factors can influence the potential for a fly ash to be marketed for utilization. In this study, three coal-fired combustors, two tangentially fired and one wall-fired, all burning high-sulfur Illinois coal at the same power plant, were studied before and after conversion to low(x) combustion. In all cases, the post-conversion fly ash was higher in carbon than the pre-conversion ash from the same unit. The fly ashes in at least two of the units would appear to have post-conversion ashes which still fall within the regional guidelines for the limit of carbon (or loss on ignition).

Idioma originalEnglish
Páginas (desde-hasta)219-229
Número de páginas11
PublicaciónWaste Management
Volumen17
N.º4
DOI
EstadoPublished - 1998

ASJC Scopus subject areas

  • Waste Management and Disposal

Huella

Profundice en los temas de investigación de 'Case study of the conversion of tangential- and wall-fired units to low- NO(x) combustion: Impact on fly ash quality'. En conjunto forman una huella única.