Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Combined in vivo amperometric oximetry and electrophysiology in a single sensor: A tool for epilepsy research

  • Ana Ledo
  • , Cátia F. Lourenço
  • , João Laranjinha
  • , Greg A. Gerhardt
  • , Rui M. Barbosa

Producción científica: Articlerevisión exhaustiva

26 Citas (Scopus)

Resumen

Seizures are paroxysmal events in which increased neuronal activity is accompanied by an increase in localized energetic demand. The ability to simultaneously record electrical and chemical events using a single sensor poses a promising approach to identify seizure onset zones in the brain. In the present work, we used ceramic-based platinum microelectrode arrays (MEAs) to perform high-frequency amperometric recording of local pO2 and local field potential (LFP)-related currents during seizures in the hippocampus of chronically implanted freely moving rats. Resting levels of O2 in the rodent brain varied between 6.6 ± 0.7 μM in the dentate gyrus (DG) region of the hippocampus and 22.1 ± 4.9 μM in the cerebral cortex. We also observed an expected increase in hippocampal pO2 (15 ± 4% from baseline) in response to tail pinch stress paradigm. Finally, induction of status epilepticus by intrahippocampal injection of pilocarpine induced biphasic changes in pO2 in the hippocampus. The initial dip at seizure onset (ΔO2 = -4.5 ± 0.7 μM) was followed by a prolonged hyperoxygenation phase (ΔO2 = +10.4 ± 2.9 μM). By acquiring the amperometry signal with a high sampling rate of 100 Hz we decomposed the raw signal in an oximetry recording (<1 Hz) and LFP recording (>1 Hz), demonstrating that each individual Pt site can simultaneously report changes in local pO2 and LFP-related currents during pilocarpine-induced seizure activity. This has high potential for translation into the clinical setting supported on intracranial grid or strip electrodes.

Idioma originalEnglish
Páginas (desde-hasta)12383-12390
Número de páginas8
PublicaciónAnalytical Chemistry
Volumen89
N.º21
DOI
EstadoPublished - nov 2017

Nota bibliográfica

Publisher Copyright:
© 2017 American Chemical Society.

Financiación

This work was financed by the European Regional Development Fund (ERDF), through the Centro 2020 Regional Operational Program, project CENTRO-01-0145-FEDER-000012-HealthyAging2020, the COMPETE 2020\uE0D5Operational Program for Competitiveness and Internationalization, and the Portuguese national funds via FCT\uE0D5Fundaca\u0327 \u00F5 para a Ciencia e a Tecnologia, I.P., project POCI-01-0145-FEDER-007440. C.F.L. acknowledges fellowship SFRH/BPD/82436/ 2011 from FCT.

FinanciadoresNúmero del financiador
Programa Operacional Temático Factores de Competitividade
Fundação para a Ciência e Tecnologia I.P.SFRH/BPD/82436/2011
FCTFundaca̧ õ para a Ciencia e a TecnologiaPOCI-01-0145-FEDER-007440
European Regional Development FundCENTRO-01-0145-FEDER-000012-HealthyAging2020

    ASJC Scopus subject areas

    • Analytical Chemistry

    Huella

    Profundice en los temas de investigación de 'Combined in vivo amperometric oximetry and electrophysiology in a single sensor: A tool for epilepsy research'. En conjunto forman una huella única.

    Citar esto