Use of knee joint finite element models for diagnostic purposes is challenging due to their complexity. Therefore, simpler models are needed for studies where a high number of patients need to be analyzed, without compromising the results of the model. In this study, more complex, kinetic (forces and moments) and simpler, kinetic-kinematic (forces and angles) driven finite element models were compared during the stance phase of gait. Patella and tendons were included in the most complex model, while they were absent in the simplest model. The greatest difference between the most complex and simplest models was observed in the internal-external rotation and axial joint reaction force, while all other rotations, translations and joint reaction forces were similar to one another. In terms of cartilage stresses and strains, the simpler models behaved similarly with the more complex models in the lateral joint compartment, while minor differences were observed in the medial compartment at the beginning of the stance phase. We suggest that it is feasible to use kinetic-kinematic driven knee joint models with a simpler geometry in studies with a large cohort size, particularly when analyzing cartilage responses and failures related to potential overloads.

Idioma originalEnglish
Número de artículo17351
PublicaciónScientific Reports
Volumen8
N.º1
DOI
EstadoPublished - dic 1 2018

Nota bibliográfica

Publisher Copyright:
© 2018, The Author(s).

Financiación

Financial support from University of Eastern Finland’s Doctoral Programme in Science, Technology and Computing (SCITECO), Academy of Finland (grant no. 269315, 286526 and 305138), Sigrid Juselius foundation, the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 755037), and National Institutes of Health (NIH/NIAMS P50 AR060752) are acknowledged. CSC-IT Center for Science, Finland, is acknowledged for computing resources.

FinanciadoresNúmero del financiador
National Institutes of Health (NIH)
National Institute of Arthritis and Musculoskeletal and Skin DiseasesP50AR060752, P50 AR060725
National Institute of Arthritis and Musculoskeletal and Skin Diseases
Itä-Suomen Yliopisto
Horizon 2020 Framework Programme755037
Horizon 2020 Framework Programme
H2020 European Research Council
Suomen Akatemia269315, 286526, 305138
Suomen Akatemia
Sigrid Juséliuksen Säätiö

    ASJC Scopus subject areas

    • General

    Huella

    Profundice en los temas de investigación de 'Comparison between kinetic and kinetic-kinematic driven knee joint finite element models'. En conjunto forman una huella única.

    Citar esto