Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: A multi-expert study

  • M. A. Deeley
  • , A. Chen
  • , R. Datteri
  • , J. H. Noble
  • , A. J. Cmelak
  • , E. F. Donnelly
  • , A. W. Malcolm
  • , L. Moretti
  • , J. Jaboin
  • , K. Niermann
  • , Eddy S. Yang
  • , David S. Yu
  • , F. Yei
  • , T. Koyama
  • , G. X. Ding
  • , B. M. Dawant

Producción científica: Articlerevisión exhaustiva

128 Citas (Scopus)

Resumen

The purpose of this work was to characterize expert variation in segmentation of intracranial structures pertinent to radiation therapy, and to assess a registration-driven atlas-based segmentation algorithm in that context. Eight experts were recruited to segment the brainstem, optic chiasm, optic nerves, and eyes, of 20 patients who underwent therapy for large space-occupying tumors. Performance variability was assessed through three geometric measures: volume, Dice similarity coefficient, and Euclidean distance. In addition, two simulated ground truth segmentations were calculated via the simultaneous truth and performance level estimation algorithm and a novel application of probability maps. The experts and automatic system were found to generate structures of similar volume, though the experts exhibited higher variation with respect to tubular structures. No difference was found between the mean Dice similarity coefficient (DSC) of the automatic and expert delineations as a group at a 5% significance level over all cases and organs. The larger structures of the brainstem and eyes exhibited mean DSC of approximately 0.8-0.9, whereas the tubular chiasm and nerves were lower, approximately 0.4-0.5. Similarly low DSCs have been reported previously without the context of several experts and patient volumes. This study, however, provides evidence that experts are similarly challenged. The average maximum distances (maximum inside, maximum outside) from a simulated ground truth ranged from (-4.3, +5.4) mm for the automatic system to (-3.9, +7.5) mm for the experts considered as a group. Over all the structures in a rank of true positive rates at a 2 mm threshold from the simulated ground truth, the automatic system ranked second of the nine raters. This work underscores the need for large scale studies utilizing statistically robust numbers of patients and experts in evaluating quality of automatic algorithms.

Idioma originalEnglish
Páginas (desde-hasta)4557-4577
Número de páginas21
PublicaciónPhysics in Medicine and Biology
Volumen56
N.º14
DOI
EstadoPublished - jul 21 2011

Financiación

FinanciadoresNúmero del financiador
National Institute of Biomedical Imaging and BioengineeringR01EB006193
National Institute of Biomedical Imaging and Bioengineering

    ASJC Scopus subject areas

    • Radiological and Ultrasound Technology
    • Radiology Nuclear Medicine and imaging

    Huella

    Profundice en los temas de investigación de 'Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: A multi-expert study'. En conjunto forman una huella única.

    Citar esto