Resumen
We describe a detection system designed for precise measurements of angular correlations in neutron β decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for β electron detection with energy thresholds below 10 keV, energy resolution of ∼3 keV FWHM, and rise time of ∼50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of β particles and recoil protons from neutron β decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments to determine the neutron β decay parameters B, a, and b.
| Idioma original | English |
|---|---|
| Páginas (desde-hasta) | 83-93 |
| Número de páginas | 11 |
| Publicación | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
| Volumen | 849 |
| DOI | |
| Estado | Published - mar 21 2017 |
Nota bibliográfica
Publisher Copyright:© 2016 Elsevier B.V.
Financiación
| Financiadores | Número del financiador |
|---|---|
| National Science Foundation Arctic Social Science Program | 1506459, 1205833, 1614839, 1126683, 1506320, 1306997, 1307426 |
ASJC Scopus subject areas
- Nuclear and High Energy Physics
- Instrumentation
Huella
Profundice en los temas de investigación de 'Detection system for neutron β decay correlations in the UCNB and Nab experiments'. En conjunto forman una huella única.Citar esto
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver