Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Diagnostic Accuracy of FDG PET for the Identification of Vascular Graft Infection

  • Maham Rahimi
  • , Muath Adlouni
  • , Ahmed Ibrahim Ahmed
  • , Talal Alnabelsi
  • , Ponraj Chinnadurai
  • , Mouaz H. Al-Mallah

Producción científica: Articlerevisión exhaustiva

4 Citas (Scopus)

Resumen

Background: Fluorodeoxyglucose (FDG) positron emission tomography (FDG PET/CT) can be used to identify and localize infection in patients with vascular graft infections (VGI). We aimed to evaluate the diagnostic accuracy of 18F-FDG PET/CT by defining thresholds for standardized uptake value (SUV) and tissue-to-background ratio (TBR) that would accurately identify the presence of vascular graft infection. Methods: Patients with suspected VGI were prospectively recruited and underwent 18F-FDG PET/CT scans. Diagnosis was based on clinical, laboratory and radiologic findings, and blinded to the results of the PET/CT scan. Receiver operator characteristics (ROC) curve analysis was done to determine optimal thresholds for SUV and TBR. Results: Our final cohort consisted of 28 patients with suspected VGI (mean ± SD age 67 ± 10 years, 61% men), of which 15 patients (54%) had definitive VGI. The cohort included 61% prosthetics grafts and 39% stent-grafts. The type of graft included in this study were biologic (4%), Dacron (64%) and Polytetrafluoroethylene (32%). The location of the implanted grafts was aortic (54%) and peripheral arterial reconstruction (46%). The location of the peripheral graft was 77% in lower extremity and 23% in the upper extremity (arterio-venous grafts for dialysis access). Using ROC analysis, SUV max of 4.5, SUV mean of 3.7, and a TBR of 1.6 gave the best balance between sensitivity and specificity (93%/92%, 100%/92% and 93%/92%, respectively). All thresholds had an area under the curve ≥0.93 and correct reclassification rate ≥93%. Conclusions: Our data suggests that FDG PET/CT can be used to reliably and accurately diagnose VGI. The dual anatomic-physiologic information from FDG PET/CT can complement clinical diagnosis particularly in uncertain cases.

Idioma originalEnglish
Páginas (desde-hasta)422-429
Número de páginas8
PublicaciónAnnals of Vascular Surgery
Volumen87
DOI
EstadoPublished - nov 2022

Nota bibliográfica

Publisher Copyright:
© 2022

Financiación

Funding: This work was supported by a grant from Houston Methodist-Siemens Healthineers Research Collaboration . The funding agency had no role in the study design, including collection, analysis and interpretation of data; in the writing of the report; and in the decision to submit the article for publication.

Financiadores
Houston Methodist-Siemens Healthineers Research Collaboration

    ASJC Scopus subject areas

    • Surgery
    • Cardiology and Cardiovascular Medicine

    Huella

    Profundice en los temas de investigación de 'Diagnostic Accuracy of FDG PET for the Identification of Vascular Graft Infection'. En conjunto forman una huella única.

    Citar esto