Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Direct comparison of neck pinhole dual-tracer and dual-phase MIBI accuracies with and without SPECT/CT for parathyroid adenoma detection and localization

  • Sherif I. Heiba
  • , Manli Jiang
  • , Javier Rivera
  • , Eric Genden
  • , William Inabnet
  • , Josef Machac
  • , Lale Kostakoglu

Producción científica: Articlerevisión exhaustiva

16 Citas (Scopus)

Resumen

Introduction: There is uncertainty about accuracies of dual-phase (DP) and dual-tracer (DT) parathyroid scintigraphy with the newly added SPECT/CT. Although SPECT/CT was shown to be helpful in parathyroid adenoma (PA) localization, it may not have optimal resolution as pinhole. This study directly compared diagnostic accuracies and confidences of various imaging protocols on same patients. Patients and Methods: One hundred fifty-five patients with pathologically confirmed diagnosis were included. Pinhole DP, pinhole DT, pinhole DP SPECT/CT, pinhole DT SPECT/CT, and SPECT/CT with only pinhole-delayed MIBI (D) were reviewed for accuracies and certainties of PA diagnosis/localization. Parathyroid adenomas were classified as clearly or unclearly distinguishable from thyroid. Furthermore, the contribution of pinhole DP to pinhole DT SPECT/CT was assessed. Results: Of 153 PAs, the correct diagnosis/localization was significantly higher by pinhole DT SPECT/CT than pinhole DP SPECT/CT, SPECT/CT D, pinhole DT alone, and DP alone. Parathyroid adenomas were clearly more distinguished from thyroid in pinhole DT than DP with/without SPECT/CT. Consequently, PA diagnosis certainty was higher in pinhole DT than DP, whereas PA localization certainty was higher in both with SPECT/CT. In pinhole DT SPECT/CT, the pinhole DP addition confirmed diagnosis/localization of only 24 uncertain PAs. Conclusions: In this large patient group, the accuracy and certainty of PA diagnosis/localization were higher in pinhole DT SPECT/CT than all other parathyroid scintigraphy protocols. Pinhole DT better identified PA than pinhole DP, whereas SPECT/CT improved PA localization in both protocols. Pinhole DP showed limited contribution and thus should be only considered when PA diagnosis/localization is uncertain by pinhole DT SPECT/CT.

Idioma originalEnglish
Páginas (desde-hasta)476-482
Número de páginas7
PublicaciónClinical Nuclear Medicine
Volumen40
N.º6
DOI
EstadoPublished - jun 25 2015

Nota bibliográfica

Publisher Copyright:
© 2015 Wolters Kluwer Health, Inc. All rights reserved.

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Huella

Profundice en los temas de investigación de 'Direct comparison of neck pinhole dual-tracer and dual-phase MIBI accuracies with and without SPECT/CT for parathyroid adenoma detection and localization'. En conjunto forman una huella única.