Dosimetric evaluation of intensity-modulated radiotherapy, volumetric modulated arc therapy, and helical TomoTherapy for hippocampal-avoidance whole brain radiotherapy

  • Yi Rong
  • , Josh Evans
  • , Meng Xu-Welliver
  • , Cadron Pickett
  • , Guang Jia
  • , Quan Chen
  • , Li Zuo

Producción científica: Articlerevisión exhaustiva

56 Citas (Scopus)

Resumen

Background: Whole brain radiotherapy (WBRT) is a vital tool in radiation oncology and beyond, but it can result in adverse health effects such as neurocognitive decline. Hippocampal Avoidance WBRT (HA-WBRT) is a strategy that aims to mitigate the neuro-cognitive side effects of whole brain radiotherapy treatment by sparing the hippocampi while delivering the prescribed dose to the rest of the brain. Several competing modalities capable of delivering HA-WBRT, include: Philips Pinnacle step-and-shoot intensity modulated radiotherapy (IMRT), Varian RapidArc volumetric modulated arc therapy (RapidArc), and helical TomoTherapy (TomoTherapy). Methods: In this study we compared these methods using 10 patient datasets. Anonymized planning CT (computerized tomography) scans and contour data based on fused MRI images were collected. Three independent planners generated treatment plans for the patients using three modalities, respectively. All treatment plans met the RTOG 0933 criteria for HA-WBRT treatment. Results: In dosimetric comparisons between the three modalities, TomoTherapy has a significantly superior homogeneity index of 0.15 ± 0.03 compared to the other two modalities (0.28 ± .04, p < .005 for IMRT and 0.22 ± 0.03, p < .005 for RapidArc). RapidArc has the fastest average delivery time of 2.5 min compared to the other modalities (15 min for IMRT and 18 min for TomoTherapy). Conclusion: TomoTherapy is considered to be the preferred modality for HA-WBRT due to its superior dose distribution. When TomoTherapy is not available or treatment time is a concern, RapidArc can provide sufficient dose distribution meeting RTOG criteria and efficient treatment delivery.

Idioma originalEnglish
Número de artículoe0126222
PublicaciónPLoS ONE
Volumen10
N.º4
DOI
EstadoPublished - abr 20 2015

Nota bibliográfica

Publisher Copyright:
© 2015 Rong et al.

ASJC Scopus subject areas

  • General

Huella

Profundice en los temas de investigación de 'Dosimetric evaluation of intensity-modulated radiotherapy, volumetric modulated arc therapy, and helical TomoTherapy for hippocampal-avoidance whole brain radiotherapy'. En conjunto forman una huella única.

Citar esto