Resumen
The effect of control devices that could be installed by homeowners on heat pumps was investigated with regard to total energy used, hourly maximum electrical demand, and spread of the demand over a monthly time period. Groups of houses had microprocessor-based thermostats and outdoor heat pump thermostats installed. The major results obtained were: (1) the microprocessor-based setback thermostats significantly reduced the total energy used (20. 4%) and the maximum demand, and (2) the outdoor heat pump thermostats significantly reduced the total energy used (7. 9%) and the maximum demand.
| Idioma original | English |
|---|---|
| Páginas (desde-hasta) | 578-587 |
| Número de páginas | 10 |
| Publicación | ASHRAE Transactions |
| Volumen | 93 |
| N.º | pt 1 |
| Estado | Published - 1987 |
ODS de las Naciones Unidas
Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible
-
Affordable and clean energy
ASJC Scopus subject areas
- Building and Construction
- Mechanical Engineering
Huella
Profundice en los temas de investigación de 'ELECTRICAL ENERGY CONSUMPTION AND DEMAND REDUCTION USING HEAT PUMP CONTROLS.'. En conjunto forman una huella única.Citar esto
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver