Resumen
Electrochemically reduced glassy carbon (r-GC) showed a superior electrochemical sensing performance, compared to oxidized GC (ox-GC) and untreated GC for the oxidation of 4 DNA bases and neurotransmitters (epinephrine, norepinephrine and serotonin). r-GC exhibited not only the largest current intensities of all redox biomolecules, but also displayed an excellent selectivity in detecting coexisting redox biomolecules. The enhanced performance of r-GC was attributed to the improved surface cleanliness of electrode and its catalytic surface functional groups. The results presented herein imply that simple electrochemical treatments are a viable method to produce sensitive and selective electrodes for label-free biosensing.
| Idioma original | English |
|---|---|
| Páginas (desde-hasta) | 2581-2587 |
| Número de páginas | 7 |
| Publicación | Electroanalysis |
| Volumen | 27 |
| N.º | 11 |
| DOI | |
| Estado | Published - nov 1 2015 |
Nota bibliográfica
Publisher Copyright:© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ASJC Scopus subject areas
- Analytical Chemistry
- Electrochemistry
Huella
Profundice en los temas de investigación de 'Electrochemical Treatment of Glassy Carbon for Label-Free Detection of DNA Bases and Neurotransmitters'. En conjunto forman una huella única.Citar esto