Electronic health record phenotype in subjects with genetic variants associated with arrhythmogenic right ventricular cardiomyopathy: A study of 30,716 subjects with exome sequencing

Christopher M. Haggerty, Cynthia A. James, Hugh Calkins, Crystal Tichnell, Joseph B. Leader, Dustin N. Hartzel, Christopher D. Nevius, Sarah A. Pendergrass, Thomas N. Person, Marci Schwartz, Marylyn D. Ritchie, David J. Carey, David H. Ledbetter, Marc S. Williams, Frederick E. Dewey, Alexander Lopez, John Penn, John D. Overton, Jeffrey G. Reid, Matthew LeboHeather Mason-Suares, Christina Austin-Tse, Heidi L. Rehm, Brian P. Delisle, Daniel J. Makowski, Vishal C. Mehra, Michael F. Murray, Brandon K. Fornwalt

Producción científica: Articlerevisión exhaustiva

39 Citas (Scopus)

Resumen

PurposeArrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited heart disease. Clinical follow-up of incidental findings in ARVC-associated genes is recommended. We aimed to determine the prevalence of disease thus ascertained.MethodsIndividuals (n = 30,716) underwent exome sequencing. Variants in PKP2, DSG2, DSC2, DSP, JUP, TMEM43, or TGFβ3 that were database-listed as pathogenic or likely pathogenic were identified and evidence-reviewed. For subjects with putative loss-of-function (pLOF) variants or variants of uncertain significance (VUS), electronic health records (EHR) were reviewed for ARVC diagnosis, diagnostic criteria, and International Classification of Diseases (ICD-9) codes.ResultsEighteen subjects had pLOF variants; none of these had an EHR diagnosis of ARVC. Of 14 patients with an electrocardiogram, one had a minor diagnostic criterion; the rest were normal. A total of 184 subjects had VUS, none of whom had an ARVC diagnosis. The proportion of subjects with VUS with major (4%) or minor (13%) electrocardiogram diagnostic criteria did not differ from that of variant-negative controls. ICD-9 codes showed no difference in defibrillator use, electrophysiologic abnormalities or nonischemic cardiomyopathies in patients with pLOF or VUSs compared with controls.ConclusionpLOF variants in an unselected cohort were not associated with ARVC phenotypes based on EHR review. The negative predictive value of EHR review remains uncertain.

Idioma originalEnglish
Páginas (desde-hasta)1245-1252
Número de páginas8
PublicaciónGenetics in Medicine
Volumen19
N.º11
DOI
EstadoPublished - nov 1 2017

Nota bibliográfica

Funding Information:
This work was supported in part by the Regeneron Genetics Center, Geisinger Health System, and the National Institutes of Health (grant DP5 OD012132). We acknowledge all participants in the GHS MyCode Community Health Initiative.

Financiación

This work was supported in part by the Regeneron Genetics Center, Geisinger Health System, and the National Institutes of Health (grant DP5 OD012132). We acknowledge all participants in the GHS MyCode Community Health Initiative.

FinanciadoresNúmero del financiador
Regeneron Genetics Center
National Institutes of Health (NIH)DP5 OD012132
National Heart, Lung, and Blood Institute (NHLBI)F32HL123215
Geisinger Health System Foundation

    ASJC Scopus subject areas

    • Genetics(clinical)

    Huella

    Profundice en los temas de investigación de 'Electronic health record phenotype in subjects with genetic variants associated with arrhythmogenic right ventricular cardiomyopathy: A study of 30,716 subjects with exome sequencing'. En conjunto forman una huella única.

    Citar esto