Energy consumption of using HEPA-based portable air cleaner in residences: A monitoring study in Seattle, US

  • Jianbang Xiang
  • , Ching Hsuan Huang
  • , Elena Austin
  • , Jeff Shirai
  • , Yisi Liu
  • , Edmund Seto

Producción científica: Article › revisión exhaustiva

20 Citas (Scopus)

Resumen

Portable air cleaners (PACs), offering both auto and manual (adjustable) operation modes, are commonly used in residences. Compared with adjustable mode, auto mode's advantage of reducing indoor PM2.5 has been previously demonstrated. This study examines the energy consumption of such PACs in six residences recruited in Seattle, United States, and compares the power consumption between auto and adjustable modes. Each residence went through a one-week-long PAC filtration session under auto and adjustable modes, respectively. PAC power consumption, indoor PM2.5, temperature, and relative humidity (RH) were measured at 10-second intervals in each residence. A linear mixed-effects regression (LMER) model was used to compare the PAC power consumption between the two modes after adjusting for indoor PM2.5, temperature, and RH. Results show that the mean (standard deviation) PAC power consumption under adjustable and auto modes were 7.0 (3.5) and 6.8 (2.6) W, respectively. The average monthly energy consumption of continuous PAC operation was estimated to be ∼5 kWh for both modes. Based on the LEMR model, PAC power consumption under auto mode was approximately 3% larger than that under adjustable mode, after adjusting for living-room PM2.5, temperature, and RH levels. The implications for PAC operation mode selection in residential environments were discussed.

Idioma originalEnglish
Número de artículo110773
PublicaciónEnergy and Buildings
Volumen236
DOI
EstadoPublished - abr 1 2021

Nota bibliográfica

Publisher Copyright:
© 2021 Elsevier B.V.

Financiación

The study was funded by the National Institute of Environmental Health Sciences ( 5R33ES024715-05 ) and the University of Washington EarthLab.

FinanciadoresNúmero del financiador
University of Washington EarthLab
National Institutes of Health/National Institute of Environmental Health Sciences5R33ES024715-05
National Institutes of Health/National Institute of Environmental Health Sciences

    ODS de las Naciones Unidas

    Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

    1. Affordable and clean energy
      Affordable and clean energy

    ASJC Scopus subject areas

    • Civil and Structural Engineering
    • Building and Construction
    • Mechanical Engineering
    • Electrical and Electronic Engineering

    Huella

    Profundice en los temas de investigación de 'Energy consumption of using HEPA-based portable air cleaner in residences: A monitoring study in Seattle, US'. En conjunto forman una huella única.

    Citar esto