Experience with uncrossmatched blood refrigerator in emergency department

Producción científica: Articlerevisión exhaustiva

15 Citas (Scopus)

Resumen

background Uncrossmatched packed red blood cell (PRBC) transfusion is fundamental in resuscitation of hemorrhagic shock. Ready availability of uncrossmatched blood can be achieved by storing uncrossmatched blood in a blood bank refrigerator in the emergency department (ED), but could theoretically lead to inappropriate uncrossmatched use. Methods This retrospective study was performed at a level I trauma center from January 2013 to March 2014. Possibly inappropriate transfusion was defined as patients who received at least one unit of blood from the ED refrigerator and no more than two units of PRBC in the first 24 hours. Deaths within the first 24 hours were excluded. Patients who received blood from the ED refrigerator who received ≤2 units total in 24 hours were compared with those who received >2 units. results 158 adults received blood from the ED refrigerator. 140 (88.6%) were trauma patients. 37 (23.4%) received massive transfusion (MT). 42 (26.6%) deaths were excluded. 29 patients received ≤2 units and 87 received >2 units in the first 24 hours. The ≤2 units group had a higher systolic blood pressure (116 mm Hg vs. 102 mm Hg, p=0.042), lower base deficit (6.4 mEq/L vs. 9.4 mEq/L, p=0.032), higher hematocrit (34% vs. 30%, p=0.024), lower rate of MT protocol activation (27.6% vs. 58.6%, p=0.005), and lower rates of transfusion of fresh frozen plasma (17.2% vs. 54.0%, p=0.001) and platelets (13.8% vs. 39.1%, p=0.012). Appropriately transfused patients were more likely to have evidence of shock with active, non-compressible hemorrhage. Potentially inappropriate uses were more likely in patients either without evidence of hemorrhage or without signs of shock. Discussion Storing uncrossmatched blood in the ED is an effective way to get PRBCs transfused quickly in hemorrhaging patients and is associated with a low rate of unnecessary uncrossmatched transfusion. Provider education and good clinical judgment are imperative to prevent unnecessary use. Level of evidence Level III, therapeutic.

Idioma originalEnglish
Número de artículoe000184
PublicaciónTrauma Surgery and Acute Care Open
Volumen3
N.º1
DOI
EstadoPublished - ene 2018

Nota bibliográfica

Publisher Copyright:
© Author(s) (or their employer(s)) 2018.

ASJC Scopus subject areas

  • Surgery
  • Critical Care and Intensive Care Medicine

Huella

Profundice en los temas de investigación de 'Experience with uncrossmatched blood refrigerator in emergency department'. En conjunto forman una huella única.

Citar esto