Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Fault samples acquisition and fault feature verification of analog filters

Producción científica: Articlerevisión exhaustiva

2 Citas (Scopus)

Resumen

The frequency of the input signal is selected specially to ensure that the input frequency just exceeds the cut-off frequency of analog filters. Because input signal is restrained partly by the attenuation of analog filters, output signal is sensitive to the variation of fault components. The peak voltage of key points is measured to construct fault samples of analog filters. The relationship between fault components and fault samples is analyzed to verify that fault samples have strong fault information of analog filters. The experimental results show that high-quality fault samples can be acquired efficiently, and fault feature of samples can be verified objectively by the present method.

Idioma originalEnglish
Páginas (desde-hasta)122-127
Número de páginas6
PublicaciónChinese Journal of Electronics
Volumen26
N.º1
DOI
EstadoPublished - ene 10 2017

Nota bibliográfica

Publisher Copyright:
© 2017 Chinese Institute of Electronics.

ASJC Scopus subject areas

  • Applied Mathematics
  • Electrical and Electronic Engineering

Huella

Profundice en los temas de investigación de 'Fault samples acquisition and fault feature verification of analog filters'. En conjunto forman una huella única.

Citar esto