Feasibility of automated treatment planning for HyperArc-based stereotactic recurrent head and neck cancers using knowledge-based planning, multicriteria optimization, and dosimetric scorecards

Producción científica: Articlerevisión exhaustiva

Resumen

The development of a HyperArc-based automated stereotactic treatment planning process for recurrent head and neck (RHN) cancers using knowledge-based planning, multicriteria optimization (MCO), and dosimetric scorecards. Twenty-eight previously treated RHN HyperArc patients, prescribed 30 to 40 Gy in 5 fractions, were used to generate a RapidPlan model. An Eclipse Scripting script was created to automate the model’s use and refine the model’s output with MCO, where tradeoff exploration was guided by a dosimetric scorecard. Final dose, calculated with AcurosXB, was normalized to the original plan’s PTV D95 %. Maximum doses to organs-at-risk (OARs), target metrics, calculation/optimization times and patient-specific quality assurance results were recorded. The automated treatment planning process took on average 12.1 ± 0.9 minutes to generate the RHN RapidPlan plan and an additional 25.0 ± 2.6 minutes for MCO exploration. The GTV mean dose stayed comparable across all plans with an average decrease of 0.8 ± 0.9 Gy from the original plan to the RapidPlan and an average increase of 0.3 ± 1.2 Gy from the original plan to the MCO plan. The PTV Paddick’s conformity index received an average decrease of 0.01 ± 0.01 from original to RapidPlan and an increase of 0.02 ± 0.01 from the original plan to the MCO plan. All OAR maximum dose changes were favorable or remained within clinically acceptable dose levels for stereotactic delivery. The dose delivery accuracy for the final plans were verified with electronic portal imaging device-based portal dosimetry and an independent Monte Carlo second check reported averages of 97.2 % and 96.3 %, respectively, indicating accurate stereotactic delivery. The process established throughout this work offers an automated treatment planning routine, excluding contouring, for stereotactic RHN patients.

Idioma originalEnglish
Páginas (desde-hasta)117-123
Número de páginas7
PublicaciónMedical Dosimetry
Volumen51
N.º1
DOI
EstadoPublished - mar 1 2026

Nota bibliográfica

Publisher Copyright:
© 2025 American Association of Medical Dosimetrists.

Financiación

This work was partially supported by a grant from the Varian Medical Systems (Palo Alto, CA).

Financiadores
Varian Medical Systems

    ODS de las Naciones Unidas

    Este resultado contribuye a los siguientes Objetivos de Desarrollo Sostenible

    1. Good health and well being
      Good health and well being

    ASJC Scopus subject areas

    • Radiological and Ultrasound Technology
    • Oncology
    • Radiology Nuclear Medicine and imaging

    Huella

    Profundice en los temas de investigación de 'Feasibility of automated treatment planning for HyperArc-based stereotactic recurrent head and neck cancers using knowledge-based planning, multicriteria optimization, and dosimetric scorecards'. En conjunto forman una huella única.

    Citar esto