Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Feasibility Study of Stereotactic Radiosurgery Treatment of Glomus Jugulare Tumors via HyperArc VMAT

Producción científica: Article › revisión exhaustiva

6 Citas (Scopus)

Resumen

This study aims to report on the clinical validation and feasibility of utilizing a novel fully automated treatment planning and delivery system, HyperArc VMAT stereotactic radiosurgery (SRS) for glomus jugulare tumors (GJT). Independent dose verification of the HyperArc module via the MD Anderson's SRS head phantom irradiation and credentialing results showed compliance with the SRS treatment requirements per IROC MD Anderson's standard. Following the Alliance clinical trial, AAPM, RTOG protocols, and QUANTEC requirements, utilizing selected three-partial arc geometry of HyperArc module on TrueBeam Linac with 6MV-FFF beam, GJT SRS plans were generated for nine previously treated Gamma Knife (GK) radiosurgery patients using advanced Acuros-based algorithm to account for tissue inhomogeneity corrections and frameless immobilization with Q-fix mask and Encompass device insert. HyperArc VMAT produced highly conformal SRS dose distributions to GJT, a steep dose gradient around the GJT, and spared adjacent critical organs including the spinal cord (< 3.0 Gy). Due to faster patient setup and less MLC modulation through the target (average beam-on time, 6.2 minutes), the HyperArc VMAT plan can deliver a single high-dose of 18 Gy to the GJT in less than 15 minutes overall treatment time, significantly improving patient comfort and clinic workflow. Pretreatment portal dosimetry quality assurance results and independent dose verification via Monte Carlo-based physics second check met our clinical SRS protocol's requirements for treatment. Due to the highly conformal dose distribution, rapid dose fall-off, excellent sparing of adjacent critical organs, and highly precise and accurate treatment, clinical implementation of frameless HyperArc VMAT for GJT patients who may not have access to nor tolerate frame-based GK SRS treatment are underway.

Idioma originalEnglish
Páginas (desde-hasta)307-311
Número de páginas5
PublicaciónMedical Dosimetry
Volumen47
N.º4
DOI
EstadoPublished - dic 1 2022

Nota bibliográfica

Publisher Copyright:
© 2022 American Association of Medical Dosimetrists

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Oncology
  • Radiology Nuclear Medicine and imaging

Huella

Profundice en los temas de investigación de 'Feasibility Study of Stereotactic Radiosurgery Treatment of Glomus Jugulare Tumors via HyperArc VMAT'. En conjunto forman una huella única.

Citar esto